DFM & Design Tips

Cable-Gland Hole Arrays: Locknut and Wrench Access

Lay out cable-gland plate hole arrays using actual glands, locknuts and installation tools, with access checks for dense OEM control-cabinet assemblies.

DRAmetal Engineering Team October 18, 2026 5 min read
Cable-Gland Hole Arrays: Locknut and Wrench Access

A cable-gland array can have correct hole diameters and still be impossible to tighten in its installed location. The gland body, internal locknut and tool each occupy a different envelope. Cable order and neighboring glands add another set of constraints.

For an OEM gland plate, start from the selected hardware and its assembly sequence rather than dividing the available area into evenly spaced holes. A visually tidy array is useful only if each fitting can be secured and maintained as intended.

Overlay the actual external and internal hardware

Obtain the gland and locknut drawings for every size in the array. Include washers, seals and any accessories in the mounting stack. Two glands with the same nominal thread can have different body widths, nut shapes or assembly requirements, so thread designation alone is not a layout envelope.

Show the view from both sides of the plate. A generous outside gap may conceal internal interference between locknuts, grounding hardware or cabinet structure. Manufacturer information such as LAPP’s locknut dimensions is useful for the exact component; it is not a universal dimension for all M20 hardware.

Check the fitting array from both sides of the plate.
Check the fitting array from both sides of the plate.

Reserve the tool motion as well as its outline

Choose the intended tightening tool and review its approach, engagement and movement around the fitting. A tool that fits over a nut may not have enough room to operate. Include the cabinet wall, folded plate returns and nearby components that are absent from a flat plate drawing.

If access depends on tightening glands in a particular order, document that sequence and confirm that a later replacement remains possible. A fitting trapped permanently between installed neighbors may meet initial assembly needs but fail the project’s maintenance expectation.

EnvelopeRequired inputCheck
Gland bodySelected model outlineExternal interference
Locknut / washerActual mounting stackInternal spacing and seating
ToolSpecified assembly methodApproach and movement
Cable arrangementReleased allocation and sequenceAssembly and later access
Plate datumsHole map and cabinet interfaceArray position and pitch

Dimension the array from stable references

Locate hole centers from released datums rather than accumulating a chain of loosely controlled pitches. Identify which dimensions govern tool access and which locate the array within the cabinet opening. The overall plate, mounting holes and gland holes need a coherent relationship.

Separate nominal dimensions from measured results. In the linked project, the selected array used nominal 40 mm pitch and sampled measurements of 39.9–40.1 mm. That record should not be rewritten as a claim that every measured pitch was at least 40 mm.

A wrench needs working space between installed glands.
A wrench needs working space between installed glands.

Trial-fit a crowded configuration

Choose a first-article configuration that exercises the most restricted positions, not just a single gland in an otherwise empty plate. Install the relevant neighboring fittings and review access on both sides. Record the hardware identities and the tool used.

The customer project documented eight glands on one first-article plate, with at least 10 mm adjacent wrench clearance under its recorded assembly condition. Its 25 N·m torque was a project condition for that selected hardware, not a general tightening recommendation for all glands with the same thread.

Release the array as an assembly interface

Include the hole map, gland BOM, installation sequence and accepted first-article findings in the production package. The plate supplier can then check dimensions against the same arrangement the cabinet assembler intends to use.

When cable allocation or gland type changes, review the neighboring positions as well as the changed hole. A larger body or a different locknut can remove tool access from an unchanged fitting. The drawing revision should capture the approved array rather than leaving these changes to line-side judgment.

First-article assembly verifies the released hardware arrangement.
First-article assembly verifies the released hardware arrangement.

Review custom cable gland plates with DRAmetal using your gland BOM, hole map and assembly acceptance requirements. The gland-plate customer project shows how array measurements, actual fitting trials and grounding-stud checks were recorded separately.