A hole diameter by itself does not describe a finished gland-plate opening. A burr, irregular cut wall or damaged sealing face can interfere with the fitting even when a basic diameter measurement appears acceptable. The inspection needs to match the surfaces the hardware actually uses.

For an OEM plate order, define the required edge condition before fabrication. ‘Deburr all holes’ is useful process language, but it does not fully establish what purchasing will accept at the gland’s mounting and sealing interfaces.

Identify which surfaces perform which function

Use the selected gland drawing to identify the clearance opening, seating face and any other controlled contact. Some features provide passage, while others support a nut or seal. The edge treatment should preserve those functions rather than apply an arbitrary large chamfer everywhere.

Mark the inspection side and delivered condition. An opening may look smooth from the cutting entry side while retaining an unacceptable edge on the other side. Include both faces and the hole wall in the agreed review where the hardware or assembly process depends on them.

Inspect the hole wall and both plate faces.
Inspect the hole wall and both plate faces.

Specify burr and sharp-edge acceptance clearly

Agree a measurable limit or an approved comparator appropriate to the part, along with the method for checking it. The required approach depends on the geometry and the buyer’s acceptance plan. Avoid substituting an undefined hand-feel judgment for a drawing requirement.

Do not use bare hands to search for sharp edges. Inspection should follow the site’s safe method and use suitable tools or references. The manufacturing record can then distinguish a remaining burr from a deliberate edge break without exposing an inspector to a preventable cut hazard.

FeatureAcceptance definitionUseful evidence
Opening sizeReleased finished dimensionRecorded measurement / approved gauge
Hole wallSpecified passage or form requirementMethod addressing plate thickness
Burr / sharp edgeAgreed limit or comparatorSafe inspection record
Seating faceRequired surface conditionVisual and specified dimensional checks
Hardware fitSelected gland and stackFirst-article assembly record

Check the delivered hole rather than only the cutting program

A programmed diameter is not a measurement of the finished opening. Material, cutting conditions, subsequent finishing and coating can affect what is delivered. Inspect the relevant dimensions after the operations that can alter fit, as defined in the production plan.

Where hole-wall variation matters, agree how diameter or passage will be assessed through the thickness. A single surface measurement can miss a restriction elsewhere in the opening. Select an inspection method that addresses the released requirement without claiming that one simple gauge establishes every aspect of roundness or wall form.

Edge treatment must preserve the required seating surface.
Edge treatment must preserve the required seating surface.

Protect the sealing and mounting faces during finishing

Grinding or edge cleanup should not create uncontrolled hollows, deep scratches or excessive edge removal on a required seating face. Identify cosmetic and functional zones so the finisher knows which defects affect assembly and which are governed by appearance requirements.

After coating or another finish, check for obstructions and damage at the relevant edges. Reworking a finished opening may expose substrate or change the intended protection. Any permitted rework should follow an approved process with a corresponding reinspection, rather than an undocumented adjustment at final assembly.

Combine dimensional checks with selected-hardware fit

A first-article trial with the intended gland and mounting stack can reveal interference or poor seating that deserves further investigation. Record the fitting used and the observed condition, but retain the dimensional and edge acceptance records as well.

The linked project’s sampled Ø20.18–20.22 mm openings describe its particular nominal Ø20.2 mm pattern. They are not a general tolerance promise for all laser-cut gland holes. For another order, release the required geometry, finish and sampling plan explicitly, then inspect against that agreement.

Pair hardware fit with a traceable dimensional record.
Pair hardware fit with a traceable dimensional record.

Review custom cable gland plates with DRAmetal using your gland BOM, hole map and assembly acceptance requirements. The gland-plate customer project shows how array measurements, actual fitting trials and grounding-stud checks were recorded separately.

Need a Custom Sheet Metal Quote?

Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.

GET A FREE QUOTE →