An internal corner can meet the outside dimensions of a housing while remaining difficult to inspect or clean. The problem often comes from overlapping parts, narrow ledges or a joint hidden beneath a filter rail. A polished visible wall does not solve an inaccessible recess next to it.
For fabricated HEPA housings, review the cleaning path while the geometry is still editable. The equipment owner defines the cleaning exposure and acceptance needs. The metalwork package should make the relevant surfaces reachable and provide clear requirements for welds, transitions and final condition.
Review the surfaces behind the visible opening
Look beyond the door aperture to the underside of rails, the back of clamp mounts and the corners behind the seat frame. Ask which parts remain fitted during cleaning and which can be removed. A removable rail may improve access, but its fasteners and locating features create their own interfaces.
A simple section through each crowded corner is often more useful than a general instruction to make the housing easy to clean. Show overlaps, gaps and weld returns. Identify any intended sealed cavity and any opening that must remain accessible for inspection or drainage.

Place welds where the agreed finish is achievable
The joint arrangement should allow the selected welding and finishing tools to reach the surface. A deep narrow corner may prevent the same blending operation used on an open flange. Changing the joint position can be more practical than demanding an unspecified mirror finish after assembly.
Separate continuous sealing joints from structural welds whose spacing is defined elsewhere. Do not infer gas-tight construction from a cosmetic blend or describe every seam as a tested boundary. If leakage acceptance is required, add the specific method and scope to the purchase specification.
| Area | Drawing decision | Inspection focus |
|---|---|---|
| Inside corner | Joint and transition geometry | Accessible continuous surface |
| Filter rail | Fixed or removable arrangement | Underside and contact areas |
| Weld | Structural / sealing purpose and finish | Specified boundary and blend |
| Machined insert | Material, fixings and sequence | Accessible mating joint |
| Finished assembly | Cleaning route and acceptance scope | Edges, recesses and documented surfaces |
Specify the finish by surface and purpose
Name the material grade, intended exposure, finish direction and any measured roughness requirement. Identify measurement locations and the final assembly state. A sample coupon can help with visual acceptance, but it does not establish the condition of a hidden internal seam.
Different treatment steps solve different problems. Grinding changes geometry and appearance; post-fabrication cleaning or passivation follows a selected process. Outokumpu’s post-fabrication treatment guidance is a useful starting reference when agreeing the stainless finishing route. Chemical exposure and the completed equipment’s cleaning validation still require application-specific review.

Keep mixed-material components in the process review
A machined insert may be installed after the welded stainless shell is finished. Identify the sequence so the insert, seals and fasteners are not exposed to a treatment intended only for the shell. Where different materials meet, the design owner should review compatibility, crevices and the intended service environment.
In the linked customer project, the aluminum seal-seat frame was screw-fastened to the stainless housing. That arrangement creates a distinct assembly interface. The drawing should show how it is accessed and retained; it should not be described as a continuous welded stainless surface.
Accept the accessible, finished assembly
Inspect the actual completed surfaces with the agreed components in place. Check for sharp transitions, remaining weld spatter, inaccessible gaps and damage introduced during later assembly. Where a removable component is part of the cleaning plan, demonstrate its removal and refitting on the first article.
Record what was examined, which areas were measured and what remained outside the supplier’s delivery scope. A clean-looking housing is not, by itself, proof of filter integrity, a cleanroom class or a validated cleaning process. Keep the fabrication record focused on the physical features it actually establishes.

DRAmetal manufactures custom HEPA filter housings around released OEM interfaces. The filter-seat customer project provides a scoped example of dimensional inspection and customer trial assembly. Include your selected filter, mating details, quantities and required records when requesting a fabrication review.
Need a Custom Sheet Metal Quote?
Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.