Locating Pins and Reamed Holes in Removable Equipment Plates

Specify fixed and removable locating interfaces separately, with pin fits, reamed-hole datums, assembly sequence and repeat-installation inspection.

DRAmetal Engineering Team October 11, 2026 5 min read
Locating Pins and Reamed Holes in Removable Equipment Plates

A removable equipment plate needs two different behaviors: it should come off without unnecessary force, then return to the required position. Treating every pin and hole as a tight fit can undermine the first requirement without proving the second.

The drawing needs to distinguish the interface that retains the pin from the interface that locates the removable part. That separation is essential when specifying custom mounting plates for medical equipment, automation modules or other serviceable OEM assemblies.

Draw both interfaces instead of writing “press-fit pin”

A locating pin may be permanently retained in a fixed support while the mating plate slides over its working diameter. The retention fit and the removable fit have different purposes. Label both in the assembly section and identify which part owns each hole.

Fit designations must be checked against nominal size and the applicable drawing standard. A label such as H7/g6 does not provide one universal clearance for every pin diameter. State the actual dimensions or limits needed for procurement, and make the functional requirement clear enough for inspection planning.

Do not ask a fabricator to choose the fit from the desired marketing phrase “high precision.” Provide the acceptable insertion behavior, locating requirement, surface condition and service arrangement. If those inputs remain unresolved, record the open decision rather than implying a tested repeatability value.

Start with a stable seating arrangement

Pins do not replace the plate’s support plane. Define the surfaces that establish seating and the fasteners that provide clamping. A burr, coating ridge or trapped film under the plate can prevent it from sitting in the condition used during measurement.

Review the removal direction and the clearance around the lifted plate. A good pin-and-hole relationship is of little use if a rail, cable duct or enclosure wall prevents axial withdrawal. Include those surrounding features in the interface review even when they are outside the fabricated plate’s bill of materials.

Smooth locating pin at a finished hole in a removable metal plate
Specify the removable mating fit separately from the pin's fixed-side retention.

Avoid adding a second locator without checking constraint

When two locators establish a pattern, their spacing and permitted movement matter. Two fully constraining circular interfaces can bind if the patterns do not agree. Carr Lane’s locating-pin guidance describes pairing round and diamond pins so the second location has directional relief.

That is one possible design approach, not a universal requirement. A round-and-slot arrangement or another controlled interface may suit a different assembly. The equipment designer should select the strategy and its orientation; the manufacturing drawing should then preserve that choice through machining and inspection.

Interface questionInformation to releaseVerification state
Where is the pin retained?Fixed component and retention detailAfter the specified installation operation
Which part is removable?Mating diameter, limits and removal directionFinished mating surfaces
What establishes seating?Support plane and clamping arrangementInstalled and clamped condition
How is rotation controlled?Secondary locator and allowed movementComplete mating pattern
How is repeatability checked?Cycles, samples, references and acceptanceSame defined setup before and after cycling

Plan hole finishing around the final geometry

A reamed hole controls a finished bore characteristic, but it does not correct every upstream error in a plate. The hole’s location relative to the assembly datums still matters. Identify the stage at which the bore is finished and the datum setup used for that operation.

For formed or welded plates, decide which features need verification after the operations that can change their relationship. Specify edge breaks and the permitted finish condition at the bore. Coating or debris must not silently consume clearance that was measured on an earlier process stage.

Round and directionally relieved locating pins beside a mounting plate
The complete locating scheme determines which directions are constrained.

Define repeated-installation evidence precisely

An initial fit check and a repeated-installation test are different records. For cycling, identify the sample count, number of removals, clamping sequence, measurement references and environmental condition where relevant. State what is measured after each agreed interval or at the endpoint.

Keep the numerical result tied to that method. Do not substitute pin diameter clearance for the measured position of the assembled module. Similarly, a result from two validation samples does not describe every production item unless a separate inspection plan establishes that coverage.

Removable mounting plate seated on locating features and clamping supports
Repeat-installation checks should use the defined seating and clamping condition.

The mounting plate customer case reports project-specific repeat-installation measurements with its sample scope. For a new RFQ, provide your own interface limits and test requirement. Pair them with the round-and-slot review so locating, adjustment and clamp functions remain distinct throughout fabrication.

Need a Custom Sheet Metal Quote?

Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.

GET A FREE QUOTE →
DRAmetal Engineering Team

Team-authored manufacturing guidance. Scope, sources, corrections, and project-status labels follow our engineering content policy.