The alignment reading looks acceptable until a motor-foot bolt is tightened. The reading moves, another foot is adjusted, and the next check moves again. It is tempting to treat this as a search for the correct shim combination. Sometimes it is. Sometimes the changing reading is telling you that the motor is being pulled into a different shape each time it is secured.
Soft foot is a support problem that needs diagnosis before final alignment. The useful question is not “Which corner needs another shim?” but “Why does the machine change position or distort as the mounting joint is released and tightened?” A thickness correction is effective only when it addresses that cause.
Prepare a safe, repeatable diagnostic condition
Soft-foot checks involve mounting fasteners and can require access close to shafts or couplings. They belong within the site’s energy-isolation and machine-support procedure, performed by qualified personnel following the equipment and measurement-system instructions. Do not loosen mounting bolts on a running machine or assume that a stopped motor is isolated from every source of movement or stored energy.
Before interpreting a reading, establish the machine’s condition. Note the connected piping, conduit, couplings and other attachments that could apply forces. Record the current shim arrangement and mounting hardware. Clean and inspect accessible support faces using the approved method. A diagnosis made with debris under a foot or an unidentified stack is difficult to reproduce after the machine is disturbed.
Use the selected instrument’s soft-foot procedure and the equipment manufacturer’s mounting requirements. Bolt sequence, tightening condition and measurement locations matter. Movement measured at one position is not automatically the physical gap at every point beneath the foot. The instrument’s method and the actual contact geometry must be understood before converting a displayed result into a shim instruction.
A parallel gap is the case a flat shim addresses most directly
If a sound foot and a sound support surface are parallel but separated by a gap, a suitable uniform shim can fill that gap without forcing one edge down first. The footprint must support the intended contact region, clear the mounting features and remain seated during the prescribed tightening sequence.
The thickness selected from a box is only the start. Check the condition of the actual piece and the mating surfaces. A burr, fold or trapped particle can become a local support point. A shim that enters easily but stops against a fillet may not reach its intended position. Open-slot and closed-hole designs solve different access problems, but neither removes the need to check the full seating area.
For a defined parallel-gap correction, use a suitable material and as few layers as the approved procedure allows. A large stack of thin pieces creates many interfaces to inspect and keep clean. Do not turn a manufacturer’s stack recommendation into a universal rule for every machine; the selected equipment procedure and joint design govern the final arrangement.

An angular gap needs more than a uniform thickness change
When the foot and support are not parallel, a uniform shim raises both sides together. It does not remove the angle between them. Tightening may then pull the foot toward the base while leaving concentrated contact at one edge. The apparent improvement in a loose condition can disappear once the joint is secured.
PRUFTECHNIK’s SHAFTALIGN touch operating guidance separates parallel, angular and induced soft-foot conditions. Its angular-soft-foot discussion considers the angled contact itself and potential corrective work, rather than assuming a flat shim is sufficient.
For an actual installation, the authorized correction may involve an engineered tapered support, repair of a damaged foot or machining of an unsuitable seating surface. It should follow the machine supplier’s requirements. Improvising a staircase of small shim fragments can create poorly supported edges and an undocumented load path. A fabricator can manufacture a defined correction piece, but the required geometry must come from a sound diagnosis and an approved design.
Some apparent gaps are created outside the foot
External forces can change the mounting condition. Connected piping, a strained bracket or another attached component may pull on the equipment. A flexible base or a damaged support can also move as fasteners are tightened. Adding metal below a foot can temporarily change the reading without removing the force or restoring the support.
The distinction is important because a successful cold static adjustment does not prove that the same joint will behave correctly when connected, loaded or operated. The responsible equipment team needs to address the relevant operating and connection conditions. Do not use a shim supplier’s part inspection as a substitute for machinery commissioning.
Likewise, a compressible or contaminated stack can produce changing contact rather than a stable geometric gap. Clean, intact pieces with controlled thickness are easier to assess than a mixture of rusty, bent or heavily coated scraps. The shim-stack article explains why correct arithmetic alone cannot establish the assembled height.
Close the loop after the correction
After an approved change, repeat the soft-foot check under the same documented conditions and then complete the required alignment checks. Re-tightening can reveal a seating problem that a loose fit did not show. If readings remain unstable, return to the cause instead of indefinitely increasing the stack.
Keep a simple record of the foot location, removed and installed pieces, measured thicknesses, material, contact condition and final verification. Identify which configuration the result represents. If the machine is later moved or its attachments change, that record helps the next technician understand the original arrangement without treating it as permanently valid for every condition.
Custom metal shims and spacer plates are useful when a standard footprint does not provide the required seating or access. The best specification describes the approved correction and its inspection needs. A well-made shim can preserve a support decision; it cannot turn an unresolved mounting problem into a stable machine by itself.
Need a Custom Sheet Metal Quote?
Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.