A motor terminal box is easy to describe by its outside dimensions and difficult to purchase accurately with those dimensions alone. The box sits between a motor frame, an electrical termination arrangement and a cable installation. Each interface can belong to a different drawing owner. A quotation based only on width, height and material leaves the fabricator guessing about the features most likely to obstruct final assembly.
For custom fabricated motor terminal boxes, build the RFQ around the installed interfaces. The objective is a defined metalwork package, not an unsupported promise that a replacement housing will fit every motor with the same nominal frame size. Separate the enclosure fabrication from terminal selection, cable installation and complete-motor qualification.
Start with the actual motor-side interface
Provide the motor model and drawing revision, but do not use a model name as the only dimensional reference. Include the mounting face, its hole pattern, the cable passage through the frame and any adjacent fins, ribs or lifting features. State which face establishes height and which feature fixes orientation. A box that clears the frame in one direction may meet a cooling rib after rotation.
Distinguish the metalwork that mates directly to the frame from an adapter supplied elsewhere. If an adapter is involved, specify both interfaces and ownership of the connecting hardware. Confirm whether the box is inspected on a representative frame, a controlled fixture or dimensional references only. These are different acceptance arrangements and should not be left until the first shipment arrives.
Include the delivered surface condition of the mating face. A bare machined seat, a painted flange and a gasketed interface do not have interchangeable inspection assumptions. The finished-state flange guide explains how to communicate the measurement condition without confusing a flatness check with a sealing test.

Release the terminal-board envelope, not just its footprint
The board outline and fixing holes are necessary, but the metal box must also accommodate the installed terminals, connection links, washers, nuts and the intended tools. Ask the electrical designer for the approved component envelope and the service condition in which connections are made. Include any insulating barriers or supporting spacers as separate BOM items.
Clarify whether board supports are welded tabs, formed shelves, installed standoffs or a removable mounting plate. Each option creates a different relationship between the board datum and the enclosure. A replaceable plate can separate electrical variants from the common shell, but its fasteners and removal path still need space. It should not become an unrecorded stack of shop-floor spacers.
Specify who supplies the board and whether a real sample or an approved dimensional model is available for the first article. Do not let a successful trial with an empty board stand in for a check of the populated terminal assembly. The latter can present a very different cover-clearance and cable-bending problem.
Map the cable route from outside to inside
Record entry position relative to the installed motor, not simply as the left-hand wall of a loose box. Define the viewing direction and include the motor shaft reference or another unambiguous orientation. Then identify the selected gland, thread or clearance-hole arrangement, locknut access and the cable approach.
The cable needs a route beyond the gland. Review the path to the assigned terminal, the component supplier’s bend requirements and the space used while assembling the connection. Cable selection and electrical clearances remain the responsibility of the appropriate electrical designer. The fabricator needs the resulting approved geometry, not a request to infer it from current rating alone.
| Interface | Required input | Quotation decision |
|---|---|---|
| Motor frame | Mounting face, hole coordinates and orientation | Direct flange or separate adapter |
| Terminal board | Populated envelope, supports and fixing stack | Tabs, standoffs or removable plate |
| Cable entries | Selected glands, cables and access path | Fixed openings or removable entry panel |
| Cover | Seal, fasteners and withdrawal space | Finished assembly and service checks |
| Acceptance | Drawing revision, sample and test scope | Dimensional, assembly and separate validation records |
Define the enclosure supply boundary
List the shell, cover, mounting flange, board supports, bonding provisions, gaskets and fasteners individually. State whether purchased items are supplied installed, loose or excluded. This prevents two quotations from appearing equivalent when one includes a finished assembly and another includes only welded metalwork.
The scope also needs material grade, thickness, finish, appearance surfaces and coating masks. A general request for a steel electrical box is not enough to control a ground-contact face or a gasket seat. Route those details into the bonding and masking release before coating instructions are issued.

Keep motor approvals separate from component geometry
WEG’s W22 technical brochure describes model-dependent terminal-box positioning and directs position changes through the manufacturer. That is a useful procurement reminder: an OEM-specific arrangement cannot be generalized into universal interchangeability. The brochure is not approval for a fabricated replacement box.
For a new design, agree the complete assembly’s required verification with the motor OEM. Do not infer ingress, electrical or hazardous-area suitability from a steel grade, a gasket or a successful dimensional fit. Record which checks belong to the metalwork order and which belong to the finished motor program.

Finish with a release package that supports repeat orders
Attach a revision-controlled assembly drawing, individual metal-part drawings, BOM, finish specification and acceptance checklist. Identify unresolved dimensions explicitly and assign a decision owner. A quotation can state an assumption, but that assumption must become an approved requirement before fabrication depends on it.
After the first article, return every accepted support, entry and cover change to the controlled documents. Retain the inspected configuration and sample scope with the record. That is what allows the next box to reproduce the approved assembly rather than reproduce an outdated drawing plus undocumented installation corrections. The customer motor terminal-box project shows how mounting and cable-routing observations belong to a particular released assembly, not a universal box specification.
Need a Custom Sheet Metal Quote?
Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.
GET A FREE QUOTE →