The kit arrives with every pocket filled and the correct total piece count. At the assembly station, however, two nearly identical thicknesses have been mixed, a loose shim has no identity and nobody knows whether a bag marked “0.010” uses inches or millimeters. The manufacturing work may be correct while the delivered kit still invites an assembly error.
A multi-thickness shim kit is an information system as well as a collection of metal pieces. Its purpose is to preserve the relationship between a physical part and the adjustment the installer intends to make. That relationship has to survive receiving, open-box storage, use beside the machine and eventual replenishment.
Begin with the unit of use, not the shipping carton
Decide whether the supply is a general assortment, a machine-specific installation kit or a matched replacement set. A general assortment offers choices. An installation kit assigns pieces or allowed combinations to particular locations. A matched set may contain components that must remain associated because they were selected or verified together. Those formats need different identification rules.
For an assortment, define each compartment by part identity, outline, material, nominal thickness, units and quantity. For a machine kit, add the installation position or assembly reference. Where the set has been selected to achieve a measured stack, distinguish that verified combination from loose spares that merely share nominal sizes. A total carton quantity cannot communicate these differences.
Keep the bill of materials as the controlling list. If an alternative thickness combination is permitted, record the authorization and the selection rule. Do not let packing staff infer that two thinner pieces may replace one thicker piece simply because the nominal arithmetic matches. The stacking-interface discussion explains why the physical result can differ.
Give thickness a unit and a meaning
Thickness identification should be readable without relying on the assembler remembering a color convention or a supplier’s usual units. Keep the unit alongside the value, and avoid unnecessary mixing of inch and metric families in the same work area. If both units are shown, define which is controlling and how the secondary value is rounded.
SKF’s TMAS machinery-shim literature provides a straightforward example of thickness marked on individual shims, with packs and kits available. For custom outlines, the underlying lesson is identity at the point of use—not that every piece can safely accept the same marking method.
Also distinguish a nominal label from a measured result. “Nominal 0.20 mm” and a recorded thickness for an identified piece are different statements. If measured values are required, attach them to a part, batch or defined sample record as appropriate. A nominal mark does not become a measurement certificate when it is printed more clearly. The nominal-versus-finished-thickness guide explains how to set that requirement before procurement.

Do not damage the adjustment surface to identify it
Marking has to suit the geometry and thickness. A deep stamp can distort thin stock or create a raised feature. A label trapped between contact faces changes the installed stack. Ink or an adhesive residue may be incompatible with the specified cleanliness or surface condition. These are reasons to review the method, not reasons to abandon identification.
An approved handling tab outside the seating footprint can offer a marking location on some designs. On others, a controlled sleeve, individual bag or tray pocket is the better solution. Keep identification outside functional contact regions where possible and verify that the selected method does not alter the required outline, thickness or flatness. Any added tab must belong to the approved part design.
When a part cannot carry a durable individual mark, the handling procedure must compensate. Open one identified pack at a time, keep loose pieces associated with their carrier, and quarantine pieces whose identity is lost. Guessing from appearance or flexibility is not a reliable substitute for checking the material and thickness through an approved recovery process.
Design for the moment the box is left open
The neat condition at dispatch is not the only condition the kit will see. An installer may remove several candidate pieces, put an unused shim back or work next to an older assortment with a similar outline. A practical layout makes the correct return position obvious and prevents different materials from sharing an undivided pocket.
Use compartments or individual packages that retain thin pieces during normal handling. Dividers should not let the smallest shim migrate underneath them. Protect edges from damage and prevent hard loose components from pressing against the flat faces. The packaging choice should reflect the actual part, not just fit the outer carton efficiently.
Used and unused pieces also need a clear separation. A shim removed from service may be bent, contaminated or altered even when its mark is legible. Returning it directly to the new-parts pocket destroys that distinction. Establish an inspection and disposition route for returned pieces, and keep any accepted reuse decision associated with the relevant maintenance procedure.
Replenishment must preserve the revision, not just the thickness
A later order for “more of the 0.5 mm shims” can be ambiguous if the outline, slot width, material or contact condition has changed. Reorder by controlled part identity and revision, with thickness as one characteristic. If only one kit position changes, update the kit list and label that position rather than allowing old and new variants to drift together.
For selected or matched sets, say whether replacement is by individual piece or by complete set. If a replacement changes a verified stack, define the necessary recheck. Thickness and flatness measurements should follow the agreed method, not an improvised check at the packing bench. Inventory traceability supports the inspection record; it cannot replace it.
For custom metal shim and spacer-plate kits, include the packing and identification arrangement in the supply review alongside drawings and quantities. A clear kit does more than look organized on arrival. It keeps a controlled manufacturing result connected to the joint where that result is needed, and makes an incorrect choice easier to notice before the machine is assembled.