An interlock mounting tab is a small part of a pass-box assembly, but its position can determine whether the selected hardware can be installed and adjusted. A slot added late may create enough movement to make one prototype work without defining a repeatable production interface.
Treat the interlock and sensor provisions as controlled mechanical features. The system designer selects the devices and defines their required operating relationship; the fabricator supplies the agreed mounting geometry and verifies its physical fit.
Obtain the selected hardware information
Request current drawings for the lock, actuator, sensor, target and any supporting brackets. Identify which pieces attach to the door and which attach to the cabinet. Include the permitted adjustment and the datum used to establish their relationship.
Do not infer the required distance or orientation from a different sensor family. The actual device instructions and system design should establish those values. A generic “sensor hole” note does not define cable exit, body clearance or access to the fixing hardware.

Check open, moving and closed states
Show the relative positions with the door fully closed, partly moving and at its required open position. A device can align at closure but strike a hinge or frame during motion. Include the actual actuator and fastener projections in the model.
Where adjustment slots are approved, define the usable travel and the surfaces that clamp the device in position. Check that the fastener remains supported across the allowed range. Do not use adjustment to hide a poorly defined relationship between the door frame and the cabinet body.
| Input | Metalwork provision | Mechanical acceptance |
|---|---|---|
| Lock / actuator | Mounts and relative position | Fit in intended door states |
| Sensor / target | Approved orientation and adjustment | Reachable stable mounting |
| Connector | Coupling and cable-exit envelope | Assembly and service access |
| Cable route | Protective features and edge treatment | Clear approved path |
| Control function | System-owned requirements | Separate integrator verification |
Reserve cable and connector access
Include the selected connector envelope and approved cable route. Check whether the connector can be fitted after the device is mounted and whether its coupling can be reached for service. A folded flange should not occupy the same space as a cable bend or strain-relief part.
Identify any protective routing features and their edge condition. The fabricator should not choose the electrical cable or redefine its bend limits. Instead, the drawing should provide the interface and clearance required by the approved component information.

Inspect the completed mounting assembly
Measure the mounting features after forming and finishing, then trial fit the supplied reference hardware where required. Record which door, frame and device revisions were present. A bracket-only check does not demonstrate the assembled door-to-sensor relationship.
Keep functional testing outside the dimensional record unless it is explicitly included and performed by the responsible team. A mounting provision can pass mechanical inspection without demonstrating that the control system prevents an unwanted door sequence.
Carry configuration changes through the drawings
Replacing a sensor or interlock can alter the mount, target, cable exit and adjustment needs. Review all affected interfaces before treating the new device as interchangeable. Update the mechanical parts, assembly references and inspection fields together.
The linked cabinet project supplied metalwork while the customer installed the doors and interlock. For a similar order, identify the hardware owner and the exact trial scope in the RFQ. This gives purchasing a defined deliverable without presenting an empty cabinet as a completed or safety-qualified control system.