Two doors on opposite sides of a cabinet share one structural body. A change made to improve one door can affect the other if the frames and hinge seats use unrelated references. That is why checking each hinge bracket in isolation is not enough for a pass-through cabinet.
The fabrication drawing should define the relationship between the cabinet, both door frames and the selected hardware. The first-article assembly then checks that relationship in the intended finished and supported condition.
Use a common cabinet reference
Identify the cabinet surfaces or features that establish the door-frame relationship. Dimension hinge seats and strike locations from those references rather than from unrelated free edges. Include the direction in which each door opens and its relationship to the installation wall.
Where the customer supplies door samples, record their revision and mounting details. A trial using an earlier door can produce a misleading acceptance result even when the cabinet is measured accurately. Keep the mating part reference in the fit record.

Review hinge and strike as one closing system
The hinge controls the door movement while the strike or latch establishes the final closed relationship. Their positions need to be reviewed together with the seal and stop surfaces. Do not use the latch to force a misaligned door into position.
Check the full sweep, not only the closed edge. The door, handle and hinge hardware should clear the frame and intended surroundings throughout the required motion. If opening stops are part of the design, show their contact surfaces and the agreed final position.
| Relationship | Input to release | Check to record |
|---|---|---|
| Frame to body | Common datum and orientation | Finished frame location |
| Hinge to door | Selected hardware and mating sample | Sweep and attachment |
| Strike to closure | Stop / latch / seal arrangement | No forced misalignment |
| Closed gaps | Locations and measurement state | Values on the defined sample |
| Interlock mounts | Selected device interface | Mechanical provision, separate function test |
Define where and how gaps are measured
A general note such as “uniform gap” needs a practical inspection reference. Identify the edges, measuring locations and assembly state. State whether the door is latched, whether seals are installed and how the cabinet is supported.
The linked project recorded a 2.0 ±0.2 mm closed gap across the four sides of the checked door assemblies, with five units in that sample. That result is specific to the supplied geometry and door arrangement. It is not a universal pass-box door-gap requirement.

Sequence welding, finishing and trial assembly
Hinge seats can move relative to the body during joining, and finishing can affect contact surfaces. Plan the checks at stages that reveal those changes. A successful tack-position trial does not necessarily establish the final welded and finished relationship.
Avoid accepting a distorted door by repeatedly adjusting unrecorded hardware. Where adjustment is designed in, document its permitted range and final condition. Where a geometry change is needed, update the drawing and repeat the affected trial rather than treating the correction as an informal shop practice.
Separate mechanical closure from interlock performance
A correctly aligned pair of doors gives the control system usable mounting interfaces, but it does not prove the interlock sequence. The selected hardware, wiring, logic and system verification remain their own work package.
For quotation, provide the door drawings, hinges, strikes, seals and any interlock-related mounting information together. Request dimensional and mechanical-fit records for the supplied metalwork, then identify the customer or integrator’s later tests. This keeps acceptance focused and prevents a door-gap result from becoming an unsupported system-level claim.

Review pass-through cabinet metalwork with DRAmetal using your cabinet drawings and installation interfaces. The wall-fit and door-alignment customer project reports the specific results and samples behind one completed fabrication program.
Need a Custom Sheet Metal Quote?
Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.
GET A FREE QUOTE →