A connector outline copied from a sample is not a complete panel-cutout specification. The body may need retaining clips, mounting screws, an anti-rotation detail or a particular panel thickness. The visible opening is only one part of the interface.
For OEM power-supply metalwork, use the selected component’s current mounting drawing and check the completed panel. This is a mechanical interface task; it does not establish the electrical approval of the finished equipment.
Identify the exact mounting version
Record the component manufacturer, part number and drawing revision. A designation such as IEC C14 identifies an interface family, not every detail of the inlet’s panel attachment. Screw-mounted and snap-in versions can need different cutouts, hardware and thickness conditions.
SCHURTER’s 6100-3 screw-mounted inlet and 6100-4 snap-in inlet illustrate why the mounting version matters. Use the drawing for the purchased part; do not transfer a dimension from another model merely because the connector face is familiar.

Overlay the component and panel geometry
Compare the cutout with the complete mounting envelope, including corners, flange overlap, fixing holes and any locating edge. Identify which features locate the component and which provide clearance. A larger opening can ease insertion while reducing support or allowing unwanted movement.
Show the allowed assembled gap at a defined location. If a locating flange controls position, dimension that relationship explicitly. Avoid a general note saying to add clearance everywhere, which can change both location and retention in ways the design owner did not intend.
| Interface | Release information | Fit observation |
|---|---|---|
| Mounting version | Exact part and current drawing | Correct retention arrangement |
| Cutout | Profile, corner geometry and location | Insertion and support |
| Thickness | Finished panel stack | Clip / fastener engagement |
| Rear envelope | Approved component and connection space | No mechanical interference |
| Trial record | Sample, revision and assembly condition | Seating, gap and retention |
Include the finished thickness and surface
For a snap-in component, the retaining feature must engage the delivered panel condition. For a screw-mounted component, the fastener and bearing surfaces need the specified fit. Coating, inserted hardware and local reinforcing pieces may alter the effective stack.
Check cut edges after finishing for burrs, coating bridges or damaged contact surfaces. Do not correct a tight cutout by uncontrolled filing during assembly. If a first-article adjustment is accepted, incorporate the revised geometry and finishing requirement into the released drawing.

Reserve the rear connection and service envelope
The inlet body, terminals, mating connections and permitted cable route occupy space behind the panel. Provide the equipment designer’s required protected envelope without inventing a universal electrical clearance. Keep a folded return or fastener from intruding into that reserved region.
Review insertion and removal with the cover and neighboring parts in their intended state. A connector may be reachable before board installation but inaccessible afterward. Decide whether that sequence is acceptable and document it, rather than leaving maintenance access to be discovered during field service.
Record the fit trial at the right scope
Use the actual selected component or an approved equivalent reference for the trial. Record seating, retention, gap locations and any rocking or interference. State whether the check occurred before or after coating and whether all mounting hardware was present.
The customer project linked below recorded a uniform 0.5 mm inlet gap on ten first articles from a 500-piece trial batch. Its full mechanical assembly check used a separate three-piece sample. Keeping those scopes separate makes the result useful without implying an electrical qualification or a universal inlet-cutout allowance.

DRAmetal supplies custom power-supply enclosure metalwork to released OEM requirements. Read the mechanical-fit customer project for its specific inspection scopes, then provide your own drawings, mating components and batch plan for quotation.
Need a Custom Sheet Metal Quote?
Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.
GET A FREE QUOTE →