DFM & Design Tips

Slotted or Closed-Hole Shims? Follow the Installation Path Before Choosing

Compare slotted and closed-hole shims through installation access, contact area, retention and service needs, before changing the part profile.

DRAmetal Engineering Team November 2, 2026 5 min read
Slotted or Closed-Hole Shims? Follow the Installation Path Before Choosing

A technician can see the gap that needs correcting, but a captive stud runs through the middle of it. A closed-hole shim of the right thickness is available, yet installing it would mean lifting the component clear of the stud. An open slot appears to solve the problem immediately. Before changing the drawing, however, it is worth following the shim through the entire installation and service sequence, not just through that first gap.

An open slot changes how a part enters an assembly. It also changes the remaining contact area and the way the part can move when the joint is released. A closed hole offers a different relationship to the fastener, but it does not automatically provide accurate location or a stronger support. The appropriate choice depends on what the shim must do once access is no longer the main concern.

Draw the insertion movement, not only the finished position

In a plan view, a U-shaped slot can look generous. In the actual machine, a rib, hose bracket or adjacent mounting foot may block the lateral path. Check the swept space needed to slide the complete shim into position, including its handling tab or any projecting edge. The fastener diameter is only one obstruction.

The required opening also depends on the state of the joint during adjustment. A slot may allow insertion around a retained stud, but the supported component must still be safely unloaded or raised by the approved method. An open-sided shim is not permission to push a thin part into a loaded joint or to work near moving equipment. Follow the equipment’s isolation and support procedure before loosening mounting hardware.

For a closed-hole part, consider when it can enter the build. It may fit easily before a stud is installed or before an upper module is lowered. That can make a closed hole entirely practical for initial assembly, even where it would be inconvenient during field adjustment. Design for the intended lifecycle rather than assuming that the factory sequence and service sequence are identical.

The slot is an access feature, not the whole specification

Commercial machinery shims commonly use an open slot; the SKF TMAS product range is one example. That familiar outline should not be copied without checking the actual mounting geometry. The slot width, depth and end position must suit the selected hardware and the intended seating position.

If a slot stops too early, its rounded end can contact the stud before the shim reaches full support. If it extends unnecessarily far, it removes material from the bearing area. Clearance must also account for the real fastener arrangement rather than the nominal bolt diameter alone: sleeves, shoulders or nearby features may occupy the path.

A tab can help identify and position a small shim, but it needs a safe final location. A tab projecting into a moving envelope, a cable route or a cleaning access zone creates a new problem. Its outline and orientation should be deliberate features on the drawing.

Open-slot and closed-hole metal shims laid beside a loose bolt
Compare the insertion path and supported footprint, not just the fastener clearance.

Compare the bearing footprint that remains

Imagine two shims with the same outside dimensions and thickness. One has a small central hole; the other has a wide slot reaching from the edge. They do not leave the same material under the mating component. Whether that difference matters depends on where the load enters and where the mating surfaces actually touch.

Look at the contact region around the fastener and beneath the component, including any reliefs in the base. A large shim over a recessed area may still have only a narrow effective bearing region. A narrow slotted leg resting on a ledge can be much less useful than its outline suggests.

Do not use the shim to bridge an unsupported gap unless the equipment design specifically allows it. A thin adjustment element is not automatically a structural plate. Where the assembly needs a load-spreading member, define that part and its support separately; use the shim for the intended dimensional adjustment.

Retention needs its own decision

A closed hole can keep a shim around a stud when clamping is released, provided the surrounding assembly prevents removal over the stud. It does not necessarily locate the shim precisely. A clearance hole may still permit considerable lateral movement, and a fastener should not be assumed to act as a locating pin.

An open slot can permit withdrawal in its insertion direction when the joint is loose. During operation, retention depends on the designed joint, not on the presence of the slot alone. If migration would create a hazard or affect the function, the equipment designer should define the retention method and acceptance checks.

Avoid adding glue, a tack weld or an improvised bend merely to hold the shim during assembly. Each changes the supplied condition and can affect thickness, surface contact or future removal. Temporary assembly aids and permanent retention features belong in the released instructions, with their effect on the working faces considered.

Test the choice with a realistic service sequence

A useful trial starts with the surrounding hardware installed. Confirm that the shim can enter, seat fully and be identified after tightening. Then repeat the removal sequence using the intended tools and access. Check that the part does not snag on a raised edge or burr and that an open slot does not disguise partial seating.

For a thickness assortment, keep the profile consistent where interchangeability is intended. A thicker replacement with a different slot depth may not occupy the same position even though its nominal adjustment is correct. The shim-kit identification guide explains why shape, thickness and revision need to travel together.

When specifying custom metal shims and spacer plates, send the relevant assembly view as well as the flat profile. Showing the insertion direction, contact footprint and service restriction often resolves the open-slot versus closed-hole decision more effectively than another discussion of hole diameter. The best profile is the one that fits the approved assembly method and continues to do its job after the installer can no longer see it.