The bottom of a strainer basket often receives less attention than its cylindrical wall. The drawing specifies a diameter, height and perforation, then shows a flat end without explaining whether it is solid, perforated or supported by the housing. That omission can change both the operating flow path and the maintenance task.
There is no universally better bottom. A solid panel and a perforated panel create different boundaries for liquid and solids, and both depend on the surrounding assembly. The useful comparison starts with how the basket is installed, what it collects and what happens when it is removed.
A solid bottom is not automatically a drainage mistake
In an upright basket with a perforated wall, liquid can pass through the side while the closed bottom remains part of the structural and collection geometry. Eaton’s pipeline strainer technical guide describes its basket construction using a perforated sheet attached to a rigid top ring and a solid bottom cap. That documented design is a reminder that an end panel need not be perforated simply because the wall is.
It does not follow that every custom basket should copy that arrangement. If the lowest side openings are above the internal floor, a solid bottom can leave a liquid pocket after removal. The amount depends on the detailed geometry, installed angle and residue, not merely the word “solid.” A dished panel, projecting joint or internal ledge changes the result again.
Consider the reason for retaining a closed end. It might be part of an approved flow arrangement, a support detail or a requirement to contain collected material during handling. Record that purpose so a later request for faster draining does not inadvertently remove a necessary feature.
More holes create a possible route, not a guaranteed result
A perforated bottom provides additional openings only where they remain exposed to flow. A housing support plate beneath it may cover much of the pattern. Close clearance can restrict the exit path. Collected solids can also cover the end panel differently from the side wall.
For that reason, calculating the added hole area does not by itself establish lower operating pressure drop or longer service intervals. The complete housing, flow direction, medium and fouling behavior need to be evaluated by the system designer. The hole size and ligament guide explains why local perforation geometry is only one input.
Use the same caution with drainage claims. A bottom that drains clean water readily may hold a viscous residue or a compacted bed of particles. Drainage time and residual liquid are application questions that need defined conditions if they become acceptance requirements.

Think about the solids during removal
An upright basket can contain wet solids even after the housing has been drained. A perforated end may allow some liquid to leave during the approved lift, but it does not establish a dry handling load. A solid end may retain additional liquid below the lowest usable wall openings. In either case, blocked holes can alter the expected condition.
Hayward’s SB basket strainer instructions explicitly include allowing liquid to drain during basket removal. That maintenance consideration should inform handling design, without importing Hayward’s procedure or operating limits into a different assembly.
The equipment owner should define the credible wet contents, disposal destination and permitted removal method. Do not size a handle from the empty basket alone or assume that changing the bottom eliminates retained liquid. The wet-load and attachment article covers that separate load path.
All removal work belongs within the installed equipment’s isolation, depressurization, draining and chemical-handling procedure. Bottom geometry is not a substitute for those controls.
Support can be helpful and obstructive at the same time
A panel resting on an approved support transfers load differently from one suspended only at its perimeter. The designer needs to know which condition actually exists, including clearances and manufacturing variation. A nominal contact shown in CAD may disappear after the basket seats on its rim.
Perforations change the remaining metal section. Adding an unperforated border can provide room for the bottom joint, while also reducing the available opening area. Enlarging that border to simplify welding may affect the intended drainage route. These are connected decisions, not independent drafting details.
An added support also introduces contact surfaces. Check whether it rubs the bottom during installation, creates a hidden residue pocket or obstructs the basket’s removal path. A support that improves one load case should not be assumed acceptable for all flow directions or blocked conditions; those inputs belong in the differential-pressure review.
Compare the complete end detail
The useful design comparison includes panel material and thickness, perforation pattern, unperforated margins, joint form, internal transitions and housing contact. Compare those features in the intended orientation, with the same assumed contents and cleaning method. Otherwise, a change attributed to “solid versus perforated” may actually come from a different support or seam.
For custom perforated stainless steel strainer baskets, freeze the selected bottom on the controlled drawing rather than leaving it to a workshop convention. If drainage is important, define how it will be assessed. If the bottom is structural, supply the approved load and support assumptions. If interchangeability matters, retain the surrounding seating and removal envelope.
The right bottom is the one that fits the assembly’s flow, handling and maintenance requirements. Hole count alone cannot make that decision.
Need a Custom Sheet Metal Quote?
Send us your CAD drawings — DRAmetal's initial response target is within 24 working hours. Quotation, DFM and lead-time timing depend on file completeness and engineering scope.