An industrial control-cabinet customer needed a cable-entry plate that could be assembled consistently with its selected glands. The earlier layout left insufficient room for tightening tools and did not include dedicated grounding studs. The revised project treated the holes, hardware and assembly access as one interface.
The plate used 3 mm SPCC steel, RAL7035 powder coating and eight selected M20×1.5 glands. Sampled openings measured Ø20.18–20.22 mm, and one first-article plate was fitted at all eight gland positions. Separate sampled checks covered the M5 grounding studs and continuity after customer wiring.
A clearance-hole plate, not a tapped gland interface
The nominal openings were Ø20.2 mm clearance holes for the selected glands and locknuts. They were not M20 tapped holes. This distinction keeps the drawing consistent with the actual retention arrangement and the inspection method.
The array used nominal 40 mm pitch, with measured results of 39.9–40.1 mm. The public record reports that nominal-and-measured relationship rather than stating that every result was at least 40 mm.
The plate also included M5 grounding studs for each pair of glands, and hole identifiers linked to the cable allocation. The customer’s internal cabinet layout remains confidential.
Fabrication and the delivered mounting stack
The manufacturing route included laser cutting, bending, grounding-stud insertion, powder coating, silkscreen hole identification, actual gland fitting and packing. The plate thickness was selected within the released mounting arrangement so the chosen glands and locknuts could be assembled as intended.
The project addressed both sides of the plate. Outside gland spacing alone would not show whether an internal locknut or tightening tool could reach its position. The first-article assembly therefore used the selected hardware rather than accepting the array solely from a top-view drawing.
No general torque, sealing class or shielding performance is assigned to the plate from these fabrication details. Those outcomes depend on the complete specified assembly and its applicable validation.
Hole-array inspection of twenty plates
The dimensional record was dated September 18, 2026. Twenty plates sampled from a 500-piece batch were checked with calipers. The recorded hole diameter was Ø20.18–20.22 mm, and the array pitch was 39.9–40.1 mm.
These results apply to the measured sample and the released nominal dimensions. They are not a claim that all 500 plates received the same dimensional inspection or that the same values apply to other gland models.
The identity of the openings mattered as well as their sizes. The plate’s hole numbering linked the fabricated array to the customer’s cable plan, reducing ambiguity during assembly of the configured cabinet.
Eight-gland first-article trial
On September 18, 2026, one first-article plate was populated with all eight glands. The recorded assembly condition used 25 N·m, with at least 10 mm adjacent wrench clearance and no interference in the reviewed arrangement.
The 25 N·m value is a recorded condition for this project’s selected hardware, not a recommended tightening torque for every M20 gland. Another program should use its chosen manufacturer’s instructions and the equipment engineer’s approved assembly requirements.
The complete first-article array provided evidence of access in a populated plate. It was separate from the twenty-piece dimensional sample and did not imply that every production plate was delivered with all glands installed.
Grounding-stud checks on ten samples
The grounding record was dated September 20, 2026 and covered ten sampled plates. The M5 studs withstood a ≥50 N pull check without loosening. This describes the applied acceptance check, not the studs’ ultimate pullout capacity.
A meter continuity check after customer wiring was also reported as satisfactory. The project record did not include a numerical resistance value. This continuity check was separate from any enclosure ingress-protection or EMC validation.
| Check | Recorded result | Coverage / condition |
|---|---|---|
| Hole array | Ø20.18–20.22 mm; pitch 39.9–40.1 mm | Twenty sampled plates from 500; calipers; September 18 |
| Gland assembly | Eight positions fitted; ≥10 mm wrench clearance; no interference | One first article; project-specific 25 N·m condition; September 18 |
| M5 studs | ≥50 N pull check without loosening; continuity satisfactory after wiring | Ten sampled plates; September 20; no numerical resistance supplied |
Turning the result into a repeatable RFQ
The useful release package combines the hole map, selected glands and locknuts, finished plate thickness, grounding provisions and assembly checks. Inspection coverage should identify the dimensional sample, populated first article and stud sample separately.
Review custom cable gland plates, the hole-array tool-access guide and the first-article gauging guide when preparing another OEM batch.