This project supplied 28 split coupling guards with 56 L-shaped mounting brackets for a pump-and-drive application. The fabrication problem was to maintain the intended clearance around the coupling while making the guard fit the equipment base and open for planned maintenance. The split arrangement used an upper hinge and a lower latch, allowing access without removing the complete cover assembly.
The owner supplied actual dimensional, assembly and finish results, together with corrections to three stepped joints and two loose latches. The resulting record shows both the useful measured outcomes and the work carried forward to subsequent tooling or assembly revisions. It does not treat a running-clearance measurement as a complete machine-safety assessment.
A defined shell, reinforcement and bracket package
The guards used SPCC cold-rolled steel. The curved shell was 1.2 mm, the circumferential reinforcing ribs were 1.5 mm, and the lower mounting brackets were 2.5 mm. The finish was RAL 7035 powder coating, with anti-rust primer at welded areas. Inner edges were dressed and rounded to remove sharp burrs.
The delivered range corresponded to the customer’s 80–120 mm shaft diameters. Shaft diameter is only one application reference: the coupling body, hubs, bolt heads and installed position still define the actual rotating envelope. This delivery is not described as fitting every coupling that happens to use a shaft in that range.
The separate bracket count is important for a repeat order. Each cover needs its approved mounting arrangement, not a visually similar bracket selected later. The guard mounting-datum guide discusses how base geometry, adjustment slots and final cover position should be related in the drawing package.
First article and production checks
One first article received full-dimensional inspection and installed alignment verification. Five production guards received key-dimensional and rotating-clearance checks. The remaining pieces received appearance and burr inspection. The five-piece sample is reported as a count rather than rounding it into an exact percentage of the 28-piece shipment.
After the two halves were assembled, recorded coaxiality was ≤0.3 mm. The reported radial clearance between the inner guard surface and the coupling’s rotating body was 8–10 mm in the checked condition. This was the project clearance result; it is not a universal safe reach distance or a sufficient basis to select openings, interlocks or retention for other equipment.
The slotted brackets accommodated the project’s ±5 mm height adjustment. Checked mounting interfaces aligned with the equipment-base holes, and the fastened covers showed no reported wobble. These observations support the installed fit of the checked configuration rather than proving a load capacity or vibration endurance for every guard.
The rotating-envelope guide separates non-contact clearance from guarding access control. Both matter, but they are different design questions and should not be accepted using the same measurement alone.
Maintenance access and latch correction
The split construction opened upward about the upper hinge after release of the lower latch. This gave access for the planned maintenance activity without requiring complete removal of the cover. Opening is considered only with the equipment stopped and safely isolated according to its approved procedure; the project record does not establish an interlocked access system or access during operation.
Two latches were initially too loose, raising a concern about unintended release in a vibration environment. Their seats were adjusted on site until the locked condition was accepted. Production received feedback on the preassembly setting. No post-adjustment vibration-endurance test was supplied, so this correction is not presented as proof of a validated vibration life.
That distinction matters commercially as well as technically. A buyer can see that a fit issue was identified and corrected without being led to assume an additional qualification test took place. A repeat RFQ should identify any required vibration test and its acceptance conditions separately from the latch assembly check.
Joint alignment, edge condition and finish
Three guards had approximately 0.3 mm step mismatch at their mating joints. Adjusting the mounting-bracket height corrected the visible mismatch. Adding locating pins to future tooling was identified as the next improvement, but the record does not claim that revised tooling has already produced a measured later batch.
Measured coating thickness was 60–80 μm. The finish and edge inspections reported no sharp corners or burrs in the accepted condition and no impact-related paint loss. A reported lateral check used 300 N of manual side force without observed deformation. The supplied data does not identify the force-measurement method or sample count, so this remains a reported project check, not a rated structural proof test.
Edge finish, latch operation and shell fit were treated as separate inspection items. A smooth coating cannot establish a burr-free hidden edge, and a bracket that fits the base does not establish that the latch stays retained under every operating condition. The first-article fit guide brings those interfaces into one review without merging their acceptance criteria.
Results, corrective actions and repeat-order scope
| Check | Recorded result | Coverage or qualification |
|---|---|---|
| Halves and running envelope | Coaxiality ≤0.3 mm; radial clearance 8–10 mm | One first article and five production dimensional/clearance samples |
| Mounting brackets | ±5 mm project height adjustment; checked holes aligned | Installed fit, not a universal adjustment specification |
| Mating seams | Three 0.3 mm stepped joints corrected | Bracket adjustment completed; locating-pin tooling change planned |
| Latch retention | Two loose latch seats adjusted and locked condition accepted | No post-adjustment vibration-endurance result supplied |
| Surface finish | 60–80 μm coating; accepted edge and appearance checks | No corrosion-life claim inferred |
| Side-force observation | Reported 300 N check without observed deformation | Method and sample count not supplied; not a load rating |
The project also noted that larger shaft-size variants were not available as existing stock. They would require new fabrication review rather than automatic substitution. No fixed lead time for those variants is promised here.
For similar custom coupling guards, provide the actual coupling envelope, base mounting drawing, maintenance opening path, selected retention hardware and OEM guarding requirements. The practical value of this case is the controlled fit and visible correction history: it supports a manufacturing discussion while leaving the equipment-specific safety assessment and any additional qualification with the responsible design team.