Medical & Diagnostic Equipment

Diagnostic Equipment Chassis: Controlling Welded Datums

The chassis served as the installation datum for a diagnostic instrument. Its mounting planes and hole positions controlled the alignment of the modules above it.

Anonymous Customer Case Study

📅 September 23, 2026 ⏱ 2 min read 🏭 DRAmetal Engineering
Diagnostic Equipment Chassis: Controlling Welded Datums — component reference
Component reference image
≤0.2 mm/m Chassis flatness
≤0.1 mm Hole position
600 × 450 mm Approximate footprint
100 parts/month Production quantity

Project Overview

Application The chassis served as the installation datum for a diagnostic instrument. Its mounting planes and hole positions controlled the alignment of the modules above it.
Materials 3.0 mm Q235 cold-rolled steel.
Process Route Laser cutting → bending → welding → stress relief → CNC datum machining → powder coating → inspection.
Customer Challenge Welding distortion pushed the chassis outside its flatness allowance, leaving the upper modules out of level after assembly.

The chassis served as the installation datum for a diagnostic instrument. Its mounting planes and hole positions controlled the alignment of the modules above it.

The customer’s challenge

Welding distortion pushed the chassis outside its flatness allowance, leaving the upper modules out of level after assembly.

Material and fabrication route

3.0 mm Q235 cold-rolled steel.

Process route: Laser cutting → bending → welding → stress relief → CNC datum machining → powder coating → inspection.

Manufacturing changes

The team revised the welding sequence and fixture, added stress relief, and machined the datum faces and mounting holes after welding.

Engineering analysis

The chassis was the reference for the modules installed above it. Correcting the upper modules individually would leave the underlying datum problem unresolved. The recorded route addressed the welded chassis first through sequence control, stress relief and final machining. Flatness and hole position then described the released installation interface, making the assembly outcome easier to relate to the manufacturing changes.

Inspection and project results

Chassis flatness reached ≤0.2 mm/m and hole position reached ≤0.1 mm. The upper modules met the assembly-level leveling requirement.

Project measurement or production detailRecorded value
Chassis flatness≤0.2 mm/m
Hole position≤0.1 mm
Approximate footprint600 × 450 mm
Production quantity100 parts/month

These figures describe the project configuration and production scope above. Dimensional, material and production details are identified separately from performance tests. For a new order, the inspection method and acceptance criteria should be agreed against the released drawings.

Planning a similar OEM component

A useful RFQ for this application should make the following interfaces and acceptance requirements clear:

  • Module interface drawings.
  • Chassis datum and mounting-plane definition.
  • Post-weld machining allowances.
  • Flatness and hole-position inspection requirements.

Include the current drawing revision, mating-component information, quantities and required delivery sequence. Identifying unresolved requirements at quotation stage helps distinguish fabrication work from the equipment-level checks that the project needs.

For related manufacturing support, review our Medical Equipment Chassis and sheet metal quality capabilities. Use the existing quotation form below to share the drawing package for review.