The enclosure protected outdoor AC/DC charging equipment and its operator display.
The customer’s challenge
Water ingress, inadequate cooling and a sun-exposed display impaired charging performance and usability.
Material and fabrication route
1.5 mm Q235 steel; 2.0 mm aluminum door.
Process route: Laser cutting → bending → welding → powder coating → cooling assembly → protection testing.
Manufacturing changes
Separate cooling and water paths supported IP54 protection. A display shade and automatic brightness arrangement improved visibility.
Engineering analysis
The enclosure had to reject heat without routing water into the equipment. Separating cooling and water paths addressed that conflict, while display shading addressed the public-facing interface. The protection and full-load temperature results belong to the populated charger configuration. For another power level, internal layout and cooling requirements should be reviewed with the enclosure rather than selected after fabrication.
Inspection and project results
The configured charger showed no reported water ingress, full-load temperature rise ≤40 K and a readable display.
| Project measurement or production detail | Recorded value |
|---|---|
| Protection test | IP54 |
| Temperature rise | ≤40 K |
| Charger power | ≥120 kW |
| Operating temperature | −30 to 60°C |
These figures describe the project configuration and production scope above. Dimensional, material and production details are identified separately from performance tests. For a new order, the inspection method and acceptance criteria should be agreed against the released drawings.
Planning a similar OEM component
A useful RFQ for this application should make the following interfaces and acceptance requirements clear:
- Charger layout and heat load.
- Water drainage and cooling paths.
- Display and service interfaces.
- Full-load environmental acceptance conditions.
Include the current drawing revision, mating-component information, quantities and required delivery sequence. Identifying unresolved requirements at quotation stage helps distinguish fabrication work from the equipment-level checks that the project needs.
For related manufacturing support, review our EV Charging Enclosure and sheet metal quality capabilities. Use the existing quotation form below to share the drawing package for review.