Medical & Clean Equipment

HEPA Housing: Gel-Seal Seat and Filter Replacement Interface

A stainless filter housing for clean equipment, including the inlet flange, filter seat, compression door and upstream / downstream test-port interfaces.

Anonymous Customer Case Study

📅 October 13, 2026 ⏱ 5 min read 🏭 DRAmetal Engineering
HEPA Housing: Gel-Seal Seat and Filter Replacement Interface — component reference
Component reference image
0.05–0.08 mm Seat variation / five pieces
5 of 50 Seat inspection sample
2 units Customer trial units
105° Access-door opening

Project Overview

Application A stainless filter housing for clean equipment, including the inlet flange, filter seat, compression door and upstream / downstream test-port interfaces.
Materials 2.0 mm SUS304 housing, formed and welded 50 × 50 × 3 mm angle flange, and a machined aluminum seal frame.
Fabrication route Laser cutting, CNC bending, stainless shell and flange welding, seal-interface preparation, weld grinding, pickling / passivation and dimensional inspection.
Customer Challenge Inconsistent sealing contact after filter changes with the previous flat-gasket arrangement.
Design changes A machined gel-seal seat frame mechanically fixed with screws, four quick clamps, test-port provisions and a door opening to 105°.

A clean-equipment OEM needed a filter housing whose seating and access features remained practical during filter replacement. The existing flat-gasket arrangement produced inconsistent contact after changes, so the project addressed the seal seat, clamping arrangement and access door together.

DRAmetal supplied the fabricated housing and its defined mechanical interfaces. The customer installed the HEPA filter and fan. Five first articles from a fifty-piece batch recorded 0.05–0.08 mm variation at the inspected seal-seat points. Two separate customer trial units were assembled with the chosen filters and clamps and received a smoke check with no observed air leakage.

The interface that drove the redesign

The previous arrangement relied on a flat gasket and a seating relationship that was difficult to reproduce consistently after filter replacement. The revised design used a gel-seal interface and a machined frame to give the filter a controlled mechanical seat.

The scope included the inlet flange, filter support, compression door and test-port interfaces. The filter model and cleanroom classification remain confidential. The case therefore reports the metal assembly and its recorded checks without presenting the housing alone as a complete filtration system.

Stainless fabrication and mechanically fixed aluminum frame

The shell used 2.0 mm SUS304 stainless steel. The inlet flange used 50 × 50 × 3 mm angle, formed and welded to the specified arrangement. The stainless manufacturing route included laser cutting, CNC bending, argon-arc welding, weld grinding, pickling / passivation and dimensional review.

The machined aluminum seal frame was mechanically fixed with screws inside the stainless housing. It was not directly welded to the stainless steel. The frame and shell connection is described as an assembly interface, while the welded fabrication route applies to the specified stainless shell and flange joints.

That distinction matters for a repeat order: the aluminum frame, its machined seat and the fastening arrangement need to stay connected in the released assembly information. Treating the frame as an unspecified welded insert would describe a different construction from the one supplied.

Clamping and filter-change access

The revised assembly used four quick clamps around the filter interface. The access door opened to 105°, giving room for the planned replacement operation. Upstream and downstream port provisions were included for the customer’s equipment arrangement.

The project combined these features rather than treating the door as a cosmetic cover. The filter had to reach the intended seat, the clamps had to be accessible, and the door needed to clear the change-out path. No filter-efficiency percentage or fan performance is attributed to these metalwork changes.

Five-piece seal-seat inspection

The seal-seat record was dated September 25, 2026. Five first articles from the fifty-piece batch were checked using a granite reference plate and dial indicator readings at four corners. Recorded variation was 0.05–0.08 mm, against the project’s ≤0.1 mm requirement.

The method and sample are retained with the result. Four-corner readings describe the measured relationship at those locations; they are not presented as a continuous scan proving every point across the complete seating surface. The full fifty-piece batch is not described as receiving that same dimensional inspection.

Customer trial with the selected filter

On September 28, 2026, the customer trial covered two assembled units using the selected HEPA filters and four-clamp arrangement. The reported smoke observation found no visible air leakage in that trial condition.

This was a customer assembly observation. It does not establish filter-media efficiency, a cleanroom class or a general housing certification. Keeping the installed components and sample quantity attached to the result makes the case useful without extending it beyond the recorded acceptance task.

CheckCondition / methodRecorded resultCoverage
Seal-seat geometryGranite plate and indicator; four-corner readings; ≤0.1 mm requirement0.05–0.08 mm recorded variationFive first articles from 50; September 25, 2026
Customer filter assemblySelected HEPA filter, four clamps and smoke observationNo observed air leakageTwo customer trial units; September 28, 2026
Replacement accessReleased door and clamp arrangement105° door openingProject configuration

What to carry into another OEM housing order

The practical lesson is to specify the seal frame, housing connection, clamping and replacement path as a coordinated assembly. Inspection should then name the measured locations and the components used for any fit or functional observation.

For a new program, review custom HEPA filter housings with the selected filter interface and acceptance plan. The gel-seal interface guide and filter replacement access guide explain the drawing inputs that make the fabrication scope clearer.