Medical Equipment Cart: Frame and Worktop Stability

The cart supported bedside monitoring equipment using a frame, upright, worktop and storage compartment as a mobile structural assembly.

Anonymous Customer Case Study

📅 March 20, 2026 ⏱ 2 min read 🏭 DRAmetal Engineering
Medical Equipment Cart: Frame and Worktop Stability — component reference
Component reference image
≥100 kg Cart load test
≤1 mm Movement sway
100 mm Caster diameter
150 carts/month Production quantity

Project Overview

Application The cart supported bedside monitoring equipment using a frame, upright, worktop and storage compartment as a mobile structural assembly.
Materials Q235 steel tube; 1.5 mm cold-rolled sheet; aluminum worktop.
Process Route Tube cutting → bending → welding → grinding → powder coating → caster assembly → complete-cart inspection.
Customer Challenge The cart swayed during movement, braking was unreliable, and the worktop connection loosened.

The cart supported bedside monitoring equipment using a frame, upright, worktop and storage compartment as a mobile structural assembly.

The customer’s challenge

The cart swayed during movement, braking was unreliable, and the worktop connection loosened.

Material and fabrication route

Q235 steel tube; 1.5 mm cold-rolled sheet; aluminum worktop.

Process route: Tube cutting → bending → welding → grinding → powder coating → caster assembly → complete-cart inspection.

Manufacturing changes

Diagonal frame bracing increased stiffness. Quiet medical-use casters with dual brakes and a bolted, dowel-located worktop secured the main interfaces.

Engineering analysis

The cart problems arose at several joints: the frame swayed, braking was unreliable, and the worktop connection loosened. Bracing, dual-brake casters and dowel-located bolting addressed those interfaces individually. The outcome is therefore best understood as an assembled-cart improvement. Load, sway and caster details help a buyer compare the project with a similar bedside-equipment arrangement without reducing it to a tube-size specification.

Inspection and project results

The completed cart moved stably, braked reliably and passed the customer’s equipment safety inspection for this configuration.

Project measurement or production detailRecorded value
Cart load test≥100 kg
Movement sway≤1 mm
Caster diameter100 mm
Production quantity150 carts/month

These figures describe the project configuration and production scope above. Dimensional, material and production details are identified separately from performance tests. For a new order, the inspection method and acceptance criteria should be agreed against the released drawings.

Planning a similar OEM component

A useful RFQ for this application should make the following interfaces and acceptance requirements clear:

  • Equipment mass and worktop load.
  • Upright and worktop interfaces.
  • Caster and brake requirements.
  • Movement and stability acceptance conditions.

Include the current drawing revision, mating-component information, quantities and required delivery sequence. Identifying unresolved requirements at quotation stage helps distinguish fabrication work from the equipment-level checks that the project needs.

For related manufacturing support, review our Medical Cart and sheet metal quality capabilities. Use the existing quotation form below to share the drawing package for review.