Industrial Automation Equipment

Metal Wireway: Cover Fit, Splice Alignment and Entry Corrections

Metal wireway sections, elbows, removable covers and joining plates for equipment cable-routing interfaces.

Anonymous Customer Case Study

📅 October 19, 2026 ⏱ 6 min read 🏭 DRAmetal Engineering
Metal Wireway: Cover Fit, Splice Alignment and Entry Corrections — component reference
Component reference image
6 pieces Dimensional sample
0.3–0.6 mm Recorded splice gaps
0.2–0.3 mm Cover clearance after coating
8 locations Cable entries checked

Project Overview

Application Metal wireway sections, elbows, removable covers and joining plates for equipment cable-routing interfaces.
Material and finish 1.5 mm SPCC cold-rolled steel with RAL 7035 electrostatic powder coating; recorded coating thickness 60–80 μm.
First delivery 24 straight sections, six 45° elbows, four 90° elbows, 34 matching covers and 12 splice plates.
Assembly checks Six sampled sections for dimensions, adjacent-section splice alignment, finished cover removal and eight cable-entry locations.
Corrections and follow-up Two entry openings were enlarged and edge-protected. One transport-damaged long section was straightened and passed reinspection. The two revised entry diameters still require drawing updates.

An equipment wireway assembly needs more than individually acceptable troughs. Straight sections, elbows, covers, joining plates and cable-entry hardware must also work together after finishing and installation. In this project, DRAmetal’s first delivery combined those components in 1.5 mm SPCC cold-rolled steel, finished with RAL 7035 electrostatic powder coating.

The project recorded a six-piece dimensional sample, assembled splice and cover checks, and verification of eight cable-entry locations. It also identified corrections: two undersized openings needed enlargement, while one long section damaged during transport required straightening and reinspection. The revised entry diameters remained a drawing-update action. Keeping these findings separate gives a more useful picture of the project than a single overall pass statement.

The supply package and its interfaces

The first delivery contained 24 straight sections, six 45° elbows, four 90° elbows, 34 matching covers and 12 splice connection plates. These are component quantities, not a count of complete wireway runs or a statement that every section received full-dimensional inspection.

The manufacturing plan brought the troughs, removable covers, splice parts and cable-entry features into one assembly review. Each interface served a different purpose: the trough and support geometry established the route, splice features aligned neighboring sections, the cover overlap controlled closure and removal, and the entries accommodated selected routing accessories.

An important purchasing distinction is that this was fabricated metalwork for equipment integration. The project information does not establish a complete electrical-system rating. Cable selection, electrical segregation and final equipment acceptance remain separate design inputs. The wireway versus cable tray guide explains how to define this metalwork supply package without mixing it with open cable-support products.

Dimensional sampling and adjacent-section assembly

Six pieces were sampled for trough dimensions. Length deviations stayed within ±0.8 mm, and bend-angle deviations were ≤0.5°, meeting the drawing requirements reported for this project. These findings apply to the six-piece sample; they are not presented as full inspection of all delivered sections.

After adjacent straight sections were joined, recorded seam gaps were 0.3–0.6 mm and step mismatch was ≤0.4 mm. The splice-hole patterns aligned, and the connection remained secure after the joining plates were tightened. No tightening torque or cyclic-load test was supplied, so these observations describe the recorded trial assembly rather than a rated joint capacity.

Checking the joint in an assembled state matters because acceptable individual lengths do not describe the entire interface. End profiles, mating hole positions, the locating method and fastening sequence all affect the finished seam. For the next release, the useful record is the assembly condition and its drawing revision alongside the measured joint, not an isolated gap value without context. The splice-plate alignment guide sets out the corresponding interface questions.

Cover fit after powder coating

The recorded coating thickness was 60–80 μm. After finishing, the cover-to-trough clearance remained 0.2–0.3 mm. The overlapping cover edges fitted smoothly, and single-hand removal and refitting were reported without binding during the trial.

This outcome is specific to the checked assembly and finish condition. It is not a universal clearance specification for every wireway size, coating system or fastening arrangement. The supplied results also do not give a repeated-removal cycle count, so no service-life claim is attached to the observation.

The practical engineering lesson is to review the cover in its delivered condition. A bare-metal fit alone would not establish how the finished overlap behaves. Cover geometry, trough-end shape and coating build need to be considered together, with the removal direction and fastener access preserved in the assembly drawing. See the cover-fit and fastener-access guide for the inputs to document before quotation.

Eight cable entries checked, two corrected

The project checked eight cable-entry locations. At two locations, the original openings were too small for the selected PG16 fittings to pass through. The openings were enlarged on site, protective grommets were added, and the resulting edge deburring was accepted.

The record identifies the accessory designation but does not provide the final opening diameters. This case therefore does not prescribe a generic PG16 cutout dimension. A later production drawing needs the exact selected accessory and its approved mounting opening, including any edge-protection component that changes the interface.

Fastener heads were reported below the relevant mounting surfaces, with no interference along the internal harness route in the checked arrangement. That assembly observation does not replace a separate electrical, ingress-protection or bonding test. No results for those tests were supplied for this case.

Most importantly, the two corrected entry diameters still require updates on the production drawings. Physical rework and document closure are separate actions. A repeat batch should use the updated hole callouts and the accepted accessory arrangement rather than reproduce the original openings and rely on field modification.

Transport damage and reinspection

One 2000 mm straight section suffered minor end deformation from transport stacking. It was straightened and passed reinspection; it was not released by concession. This correction is reported separately from the original six-piece dimensional sample because the supplied information does not say that the repaired piece was part of that sample.

For future shipments, the event supports reviewing how long sections and their ends are supported and separated during stacking. Such a packaging review is a follow-up consideration, not a claimed completed corrective action or a measured reduction in shipping damage.

Recorded results and outstanding action

Check or eventRecorded resultCoverage and status
Trough dimensionsLength deviation within ±0.8 mm; bend-angle deviation ≤0.5°Six sampled pieces; drawing requirements met
Adjacent straight-section jointsGap 0.3–0.6 mm; step mismatch ≤0.4 mm; holes aligned and plates secure after tighteningTrial-assembly observations; no separate joint-test sample count supplied
Finished cover fit60–80 μm coating; remaining clearance 0.2–0.3 mm; smooth removal and refittingChecked assembly in the coated condition; no cycle-life result claimed
Cable entriesTwo undersized openings corrected by enlargement, grommets and accepted deburringEight locations checked; revised diameters still require drawing updates
Internal fastener clearanceHeads below mounting surfaces; no interference with the checked harness routeAssembly observation, not an electrical-system qualification
Transport-damaged long sectionOne 2000 mm section straightened and reinspection passedNo concession release; packaging review remains a follow-up consideration

Preparing a repeat OEM order

The batch demonstrates why dimensional sampling, assembly fit, entry correction and document revision should be recorded as separate acceptance tasks. Finished cover fit and aligned joints were achieved in the recorded trial, while the cable-entry findings exposed information that must carry into the next drawing release.

For a similar custom sheet metal wireway, supply the routing layout, section and elbow schedule, cover-removal direction, splice interfaces, selected entry accessories, material and finish. Agree which checks apply to first articles, sampled batch pieces or the complete installation. Include the corrected entry detail in the controlled drawing pack before repeat production. The entry and first-article guide provides a practical checklist for that review.

More Manufacturing Projects

Explore More Manufacturing Work