Outdoor Cabinet Bodies
Wall-mount, pole-mount and floor-standing enclosure bodies for telecom and base station mechanical platforms.
DRAmetal manufactures build-to-print 5G equipment and base station enclosures, including outdoor cabinet bodies, radio housings, fiber and power entry panels, mounting brackets and gasket-interface mechanical kits. Send released drawings, ingress interfaces, finish, hardware, CTQs and quantities for RFQ review; the telecom OEM owns final IP, thermal, RF/EMI and site validation.
Telecom OEMs sourcing 5G base-station enclosures need cabinet bodies, fiber-entry panels, thermal features and documented mechanical interfaces tied to buyer-defined ingress targets—not a generic outdoor box.
Wall-mount, pole-mount and floor-standing enclosure bodies for telecom and base station mechanical platforms.
Formed aluminum or steel housings, covers and brackets for radio, power and network equipment.
Gland plates, cable entry panels, grounding plates and service access covers for outdoor telecom cabinets.
Finished enclosure parts packed with hardware, gasket interfaces and site-specific mechanical kit control.
The telecom OEM or integrator owns RF design, electronics, thermal validation, IP/EMI certification and site approval. DRAmetal manufactures the sheet metal enclosure body, panels, brackets, entry plates and mechanical kits to released drawings and inspection requirements.
Cabinet format follows the released installation, radio and power envelopes, cable-entry layout, thermal architecture, service access and buyer-defined environmental interfaces.
Cabinet Weather-resistant enclosure bodies, doors, covers and mounting structures for outdoor telecom base station sites.
Radio Formed covers, chassis, brackets and shielded mechanical parts for radio, power and network equipment modules.
Entry Cable gland plates, fiber entry panels, grounding plates and access covers with controlled hole patterns and sealing lands.
Kits Finished cabinet parts, brackets, panels and hardware-ready assemblies packed by site, cabinet model or project revision.
| Materials | Galvanized steel, cold-rolled steel, 5052/6061 aluminum, 304/316 stainless steel and drawing-defined outdoor materials |
|---|---|
| Processes | Laser cutting, punching, bending, welding, hardware insertion, gasket-land preparation, powder coating, passivation and mechanical assembly |
| Part examples | Outdoor cabinet bodies, doors, covers, radio housings, fiber panels, power entry plates, grounding plates, brackets and service panels |
| Outdoor features | Gasket lands, rain lips, vent patterns, drain paths, gland plates, grounding studs, specified finishes and interfaces for buyer-defined ingress targets |
| Quality controls | First article, CTQ sealing-surface checks, hinge and latch fit, hardware presence, coating inspection and packout verification |
| Delivery format | Loose cabinet parts, hardware-installed panels, mechanical enclosure kits, site packs or export-protected assemblies |
Confirm the mechanical scope, telecom OEM interfaces, outdoor rating targets and which validation remains with the customer.
Review gasket lands, cable entries, drain features, grounding, venting, hinge/latch positions and coating requirements.
Cut, punch, bend, weld and deburr cabinet panels, covers, housings, entry plates and brackets.
Apply powder coating, passivation or plating, then install studs, PEM hardware, hinges, latches or drawing-defined hardware.
Check sealing interfaces, hole patterns, door fit, grounding points, coating quality and hardware presence.
Pack parts by cabinet model, site sequence, drawing revision or telecom project milestone.
Outdoor telecom enclosures combine weather sealing, grounding, cable access, serviceability, cooling paths and field installation constraints. The manufacturer must control more than sheet metal shape.
Door openings, service panels, gland plates and cable entries need flat, repeatable gasket and compression surfaces.
Grounding studs, masked areas and conductive interfaces must match the OEM's electrical architecture.
Coating thickness, edge protection and stainless hardware matter for long-life telecom deployment.
Telecom rollouts depend on parts arriving by cabinet model, site sequence and revision, not as mixed loose components.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
Numerous cable entries admitted water, while replacing one cable required disturbing the entire seal arrangement.
Results apply to the project configuration described on the linked page.
Read the Customer Project →Telecom cabinets, electrical enclosures and control cabinets give us practical experience with sealing, coating and hardware interfaces.
We align fabrication to released drawings, BOMs, coating notes, hardware lists and approved deviations.
Sealing lands, cable entries, doors, grounding points and mounting features are checked against functional requirements.
Panels and cabinet kits can be packed by project, cabinet type, site sequence and revision for deployment teams.
We fabricate outdoor cabinet bodies, doors, panels, radio housings, brackets, cable entry plates, grounding plates, gland plates, covers and hardware-ready mechanical kits.
No. We manufacture drawing-defined mechanical interfaces for the buyer's ingress target. The telecom OEM, integrator or accredited test provider owns final enclosure validation and certification.
Yes. We can pack finished parts and mechanical kits by project site, cabinet model, drawing revision or deployment sequence.
Send drawings, STEP files, material and coating requirements, gasket details, cable entry layout, grounding requirements, hardware list, inspection points and forecast quantity.
Send your telecom enclosure drawings, gasket details, cable entry layout, material and finish notes, hardware list, CTQ features and deployment quantity. We will review manufacturability and inspection risk before quoting.