5G Base Station Enclosure Manufacturer

5G Base Station
Enclosure
Outdoor Telecom Mechanical Kits

DRAmetal manufactures build-to-print 5G equipment and base station enclosures, including outdoor cabinet bodies, radio housings, fiber and power entry panels, mounting brackets and gasket-interface mechanical kits. Send released drawings, ingress interfaces, finish, hardware, CTQs and quantities for RFQ review; the telecom OEM owns final IP, thermal, RF/EMI and site validation.

✓ Build-to-print scope
✓ Inspection by RFQ
✓ OEM approval boundary
5G base station enclosure parts inspected in a telecom sheet metal factory
RFQ Project-defined
RFQ
Example order size
Drawing
Critical dimensions
Plan
Inspection scope
OEM
Final approval
01 / What We Fabricate

Mechanical Enclosures for 5G Base Station Equipment

Telecom OEMs sourcing 5G base-station enclosures need cabinet bodies, fiber-entry panels, thermal features and documented mechanical interfaces tied to buyer-defined ingress targets—not a generic outdoor box.

Outdoor Cabinet Bodies

Wall-mount, pole-mount and floor-standing enclosure bodies for telecom and base station mechanical platforms.

Radio Equipment Housings

Formed aluminum or steel housings, covers and brackets for radio, power and network equipment.

Fiber and Power Entry Panels

Gland plates, cable entry panels, grounding plates and service access covers for outdoor telecom cabinets.

Site-Specific Mechanical Kits

Finished enclosure parts packed with hardware, gasket interfaces and site-specific mechanical kit control.

Our scope: mechanical enclosure fabrication for telecom OEMs

The telecom OEM or integrator owns RF design, electronics, thermal validation, IP/EMI certification and site approval. DRAmetal manufactures the sheet metal enclosure body, panels, brackets, entry plates and mechanical kits to released drawings and inspection requirements.

02 / Telecom Enclosure Types

5G Cabinet Bodies, Housings and Entry Panels

Cabinet format follows the released installation, radio and power envelopes, cable-entry layout, thermal architecture, service access and buyer-defined environmental interfaces.

Outdoor Base Station Cabinet Bodies Cabinet

Outdoor Base Station Cabinet Bodies

Weather-resistant enclosure bodies, doors, covers and mounting structures for outdoor telecom base station sites.

  • Format Wall / pole / floor
  • Features Doors, vents, glands
  • Use 5G outdoor sites
Radio Equipment Housings Radio

Radio Equipment Housings

Formed covers, chassis, brackets and shielded mechanical parts for radio, power and network equipment modules.

  • Materials Aluminum, steel, stainless
  • Control Grounding and fit
  • Finish Powder coat / passivate
Fiber and Power Entry Panels Entry

Fiber and Power Entry Panels

Cable gland plates, fiber entry panels, grounding plates and access covers with controlled hole patterns and sealing lands.

  • Features Glands, knockouts, studs
  • Inspection Hole and gasket checks
  • Use Base station support
Telecom Site Mechanical Kits Kits

Telecom Site Mechanical Kits

Finished cabinet parts, brackets, panels and hardware-ready assemblies packed by site, cabinet model or project revision.

  • Packout Site and model
  • Quality Hardware check
  • Docs Revision controlled
03 / Technical Capabilities

Typical 5G Base Station Enclosure Specification

Materials Galvanized steel, cold-rolled steel, 5052/6061 aluminum, 304/316 stainless steel and drawing-defined outdoor materials
Processes Laser cutting, punching, bending, welding, hardware insertion, gasket-land preparation, powder coating, passivation and mechanical assembly
Part examples Outdoor cabinet bodies, doors, covers, radio housings, fiber panels, power entry plates, grounding plates, brackets and service panels
Outdoor features Gasket lands, rain lips, vent patterns, drain paths, gland plates, grounding studs, specified finishes and interfaces for buyer-defined ingress targets
Quality controls First article, CTQ sealing-surface checks, hinge and latch fit, hardware presence, coating inspection and packout verification
Delivery format Loose cabinet parts, hardware-installed panels, mechanical enclosure kits, site packs or export-protected assemblies
04 / Manufacturing Process

From Telecom Drawing Review to Site-Ready Packout

01

Enclosure Boundary Review

Confirm the mechanical scope, telecom OEM interfaces, outdoor rating targets and which validation remains with the customer.

02

DFM and Sealing Review

Review gasket lands, cable entries, drain features, grounding, venting, hinge/latch positions and coating requirements.

03

Fabrication

Cut, punch, bend, weld and deburr cabinet panels, covers, housings, entry plates and brackets.

04

Finish and Hardware

Apply powder coating, passivation or plating, then install studs, PEM hardware, hinges, latches or drawing-defined hardware.

05

Mechanical Inspection

Check sealing interfaces, hole patterns, door fit, grounding points, coating quality and hardware presence.

06

Site Kit Packout

Pack parts by cabinet model, site sequence, drawing revision or telecom project milestone.

05 / Why It Matters

Why 5G Enclosure Manufacturing Needs Telecom-Specific Controls

Outdoor telecom enclosures combine weather sealing, grounding, cable access, serviceability, cooling paths and field installation constraints. The manufacturer must control more than sheet metal shape.

Sealing Interfaces

Door openings, service panels, gland plates and cable entries need flat, repeatable gasket and compression surfaces.

Grounding and EMI

Grounding studs, masked areas and conductive interfaces must match the OEM's electrical architecture.

Outdoor Finish

Coating thickness, edge protection and stainless hardware matter for long-life telecom deployment.

Site Packout

Telecom rollouts depend on parts arriving by cabinet model, site sequence and revision, not as mixed loose components.

Customer Project

5G Cabinet Cable Entries: Modular Sealing

Materials, fabrication decisions and results for an anonymous customer project.

5G Cabinet Cable Entries: Modular Sealing — component reference

Component reference image

The Customer Challenge

Numerous cable entries admitted water, while replacing one cable required disturbing the entire seal arrangement.

Project Measurements & Details

IP65Protection test
≥8Cable entries
−40 to 70°CTemperature range

Results apply to the project configuration described on the linked page.

Read the Customer Project →
07 / Why Choose Us

Why Telecom OEMs Use DRAmetal for 5G Enclosures

01

Outdoor enclosure experience

Telecom cabinets, electrical enclosures and control cabinets give us practical experience with sealing, coating and hardware interfaces.

02

Build-to-print discipline

We align fabrication to released drawings, BOMs, coating notes, hardware lists and approved deviations.

03

Mechanical inspection focus

Sealing lands, cable entries, doors, grounding points and mounting features are checked against functional requirements.

04

OEM-ready delivery

Panels and cabinet kits can be packed by project, cabinet type, site sequence and revision for deployment teams.

09 / FAQ

5G Base Station Enclosure FAQ

What 5G enclosure parts can DRAmetal fabricate?

We fabricate outdoor cabinet bodies, doors, panels, radio housings, brackets, cable entry plates, grounding plates, gland plates, covers and hardware-ready mechanical kits.

Can you certify IP65 or IP66?

No. We manufacture drawing-defined mechanical interfaces for the buyer's ingress target. The telecom OEM, integrator or accredited test provider owns final enclosure validation and certification.

Can parts be packed by site or cabinet model?

Yes. We can pack finished parts and mechanical kits by project site, cabinet model, drawing revision or deployment sequence.

What should be included in a telecom enclosure RFQ?

Send drawings, STEP files, material and coating requirements, gasket details, cable entry layout, grounding requirements, hardware list, inspection points and forecast quantity.

Get Started

Need 5G Base Station Enclosures
Built to Your Drawings?

Send your telecom enclosure drawings, gasket details, cable entry layout, material and finish notes, hardware list, CTQ features and deployment quantity. We will review manufacturability and inspection risk before quoting.