Drawing-led component supply
Plate outline, mounting pattern, opening, sealing interface and installation datums.
Order fabricated gland plates around your selected cable glands, cabinet opening and assembly sequence. DRAmetal reviews hole arrays, plate thickness, access, finish and inspection for prototype and repeat production batches. Related fabrication family · Customer project and inspection scope
A gland plate is a configured mounting interface, not just a metal blank with holes. We produce the released plate and specified hardware provisions, while the OEM defines the selected gland system, sealing arrangement, electrical requirements and complete cabinet acceptance.
Plate outline, mounting pattern, opening, sealing interface and installation datums.
Exact glands, locknuts, washers, seals and manufacturer installation instructions.
Agree the finished-part dimensions and actual mating components before the trial, with the method and quantity recorded for each acceptance task.
Separate prototype, pilot and repeat-order demand, with approved revisions, kit content and surface protection carried into the supply plan.
Plate outline, mounting pattern, opening, sealing interface and installation datums. Exact glands, locknuts, washers, seals and manufacturer installation instructions. Stable hole identifiers, clearance or tapped features, sizes, positions and permitted variants.
The options below describe fabrication scope. Dimensions, material, hardware and acceptance conditions are agreed for the individual drawing and BOM.
Pre-Cut Gland Metal plates with identified openings positioned around the actual gland bodies, locknuts and installation tools.
Split Support Multi-part metal supports designed around an approved split entry system and pre-terminated harness assembly path.
Blank or Drawing-led delivery states with the remaining hole-making work and acceptance responsibility explicitly defined.
Grounding-Provision Plates Gland plates with specified studs, contact areas or associated brackets reviewed with the equipment electrical team.
| Cabinet interface | Plate outline, mounting pattern, opening, sealing interface and installation datums. |
|---|---|
| Gland BOM | Exact glands, locknuts, washers, seals and manufacturer installation instructions. |
| Hole map | Stable hole identifiers, clearance or tapped features, sizes, positions and permitted variants. |
| Mounting stack | Finished plate thickness and the complete thread, seal, washer and nut arrangement. |
| Tool space | Access on both sides, populated-array assembly sequence and service requirements. |
| Grounding details | Specified studs, contact provisions and the required separate checks. |
| Finish and edges | Material, coating, finished-hole dimensions, burr limits and sealing-face acceptance. |
| Production plan | First article, sampled batch checks, quantity, configuration identification and packing. |
Coordinate the cabinet opening, gland hardware and released hole map.
Make the specified plate outline, openings and formed features.
Install approved studs or other components and preserve the required contact details.
Complete edge treatment, coating and identification in the delivered condition.
Inspect the agreed sample and trial-fit the selected populated hardware arrangement.
Pack plates against the approved variant and revision, with the contracted inspection records.
Review these interfaces before accepting an overall envelope or material label as a complete purchasing specification.
Clearance holes retained by locknuts are not the same interface as tapped mounting holes.
Review wrench movement and internal locknuts, not only the outside gland spacing.
The entire plate, seal, washer and nut stack consumes the available mounting length.
Array dimensions, stud checks, continuity and environmental sealing require their own evidence.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
The earlier hole layout left inadequate wrench space and provided no dedicated grounding studs.
Results apply to the project configuration described on the linked page.
Read the Customer Project →Review the mating components, unresolved interfaces and acceptance requirements before they become manufacturing assumptions.
Define the fabricated parts and bought-in components in one controlled supply BOM, with clear assembly responsibility.
Request the dimensional report, first-article trial and other project documentation at quotation, with explicit sample coverage.
Retain approved drawings, component identities, finish references and packaging rules for recurring business orders.
This page covers custom metal support plates and specified hardware provisions for OEM assemblies. Identify any bought-in entry system separately in the RFQ.
Yes. Supply the exact hardware and hole map, then review tool access and the complete mounting stack at each position.
No. State whether the fitting uses a clearance opening and locknut or a specified threaded interface. The linked project used clearance holes for selected M20×1.5 glands.
A split metal support can be reviewed around an approved split entry system. The joint, cable handling and sealing arrangement need their own released design and validation.
No performance rating is inferred from the metalwork alone. The complete cabinet, glands, seals and bonding arrangement need the applicable project verification.
Send the plate drawing, cabinet interface, gland BOM, stack and tool access, material and finish, quantities, variants and required inspection scope.
Share the controlled drawings, mating interfaces, material and finish, quantities and acceptance requirements for an engineering quotation.
Certification documents are available for supplier qualification. Mention the required standard and project scope in your inquiry.