Coupling-specific metalwork
Fabricated guard geometry for approved shaft, hub, spacer and fastener envelopes, with the nearest internal features included in the fit review.
Source fabricated coupling guard shells, end plates, mounting brackets and selected hardware as one defined OEM package. DRAmetal works from your approved rotating envelope, base interfaces, maintenance procedure and protective geometry—not a nominal shaft diameter alone. Perimeter machine guarding · Customer coupling-guard project
The purchased metalwork must fit the released pump–motor or drive configuration, remain clear of the approved rotating envelope and support the defined maintenance sequence. Our scope can include formed shells, end plates, brackets, stiffeners and specified attachment hardware. The OEM defines the risk assessment, protective requirements, interlocking where needed and complete-machine validation.
Fabricated guard geometry for approved shaft, hub, spacer and fastener envelopes, with the nearest internal features included in the fit review.
Mounting feet and brackets tied to released datums, permitted adjustment and the final secured condition.
Lift-off, split or hinged forms selected around the authorized service task, handling space and retention requirements.
Identified shells, handed plates, brackets and hardware supplied against a controlled BOM for pilot builds and recurring equipment variants.
Include the coupling and drive configuration, base references, nearby obstructions, approved protective geometry, service task and inspection scope. These inputs allow a meaningful engineering review and a comparable fabrication quotation.
Component forms are selected around the approved machine design. Geometry, material, retention and acceptance requirements are released for each project; a shape or material alone does not establish a safety rating.
Continuous Shell Formed covers with a defined removal path and mounting interface, suited to projects where the complete shell can be withdrawn through the available space.
Matched Sections Two or more sections with controlled seam alignment, attachment hardware and orientation, allowing the approved cover sections to be removed separately.
Retained Access Hinged metalwork with agreed movement, stops and retention. Any required interlock hardware, control integration and validation are explicitly assigned in the supply scope.
Variant Interfaces Custom profiles and end interfaces for released drive variants with unequal diameters, offsets or nearby equipment constraints.
| Equipment configuration | Pump, motor or drive identities; coupling model, hubs, spacers, fastener arrangement and the approved variant matrix. |
|---|---|
| Rotating envelope | OEM-released geometry, shaft location and any specified operating allowances, with the coordinate reference and acceptance conditions. |
| Base and mounting datums | Mounting faces, hole patterns, bracket location, permitted adjustment and the final secured assembly position. |
| Guard construction | One-piece, split or hinged form; seams, end plates, stiffeners, handling details and the required removal or opening path. |
| Material and finish | Released grades and thicknesses for shell and brackets; coating or surface treatment, appearance, masking and operating-environment inputs. |
| Retention and access | Approved fasteners, hinges, latches and any interlock scope; tool access, retention needs and maintenance isolation procedure. |
| Inspection and validation | First-article fit, dimensional locations, sampling, finished-state checks and any separately specified functional or protective testing. |
| Order configuration | Quantities, drawing revisions, handed parts, loose versus installed hardware, identification and packing requirements. |
Connect the shaft and coupling configuration to the base, adjacent equipment and approved protective geometry before detailing individual cover parts.
Define the internal profile, seams, mounting datums, adjustment limits and purchased hardware as one controlled assembly.
Produce the released sheet-metal geometry and reinforcements, with attention to inward projections, edge condition and distortion at locating surfaces.
Apply the specified finish, protect selected contact faces and install the agreed hardware without substituting unapproved lengths or retention components.
Check the specified configuration on the agreed equipment or fixture, recording measured fit, bracket settings, sample quantities and corrective actions.
Match shells, end plates and brackets to the BOM, separate hardware and protect finished surfaces for receiving and repeat assembly.
A guard may match its individual drawing while an inward fastener, bracket setting or equipment variant changes the installed relationship. Review the complete assembly condition.
Account for seams, stiffeners, folded returns and fastener ends as well as the main skin when checking the approved rotating envelope.
A slot provides defined installation movement, not unlimited compatibility. Agree the usable range, washer support and final secured location.
A hinge or latch makes a mechanical movement possible; the OEM's protective arrangement and maintenance procedure determine when access is permitted.
Keep local adjustment, reinspection and permanent drawing changes distinct so the next batch receives the intended revision.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
A 28-piece split coupling guard project with sampled alignment checks, recorded running clearances, accessible brackets and documented latch corrections.
Results apply to the project configuration described on the linked page.
Read the Customer Project →Quote shell metalwork, end plates, mounts and selected hardware together, with purchased controls or machine-level validation clearly assigned.
Separate shared guard features from variant-specific interfaces and retain identities for non-interchangeable parts.
Agree datums, finished condition, sample quantities and acceptance points so the report explains what was actually checked.
Carry accepted revisions, packing details and hardware identities into subsequent orders rather than relying on a prototype's appearance.
No. The supply scope is fabricated sheet-metal guard components and the agreed mounting or attachment hardware. The coupling, shafts, drive alignment and complete equipment are separate items unless explicitly included in a project agreement.
Yes, to the approved project drawings and BOM. Define the removable sections, movement path, retention arrangement and any interlock scope. A hinge or latch alone does not establish the required safeguarding concept.
The OEM must release the complete rotating envelope and the required separation for the applicable configuration and conditions. Shaft diameter alone is insufficient. We review the finished shell, inward hardware and mounting relationship against those inputs.
It can be reviewed against a defined configuration matrix. Provide each approved coupling, shaft location, base interface and adjacent obstruction. Available bracket adjustment does not by itself prove compatibility with every variant.
Provide the material grade, thickness and environment for engineering review. The selected structure, joining route, finish and contact surfaces must suit the approved design. A material name does not establish corrosion life or a safety rating.
Agree the equipment or fixture reference, finished-state dimensions, mounting settings, hardware checks and authorized removal sequence. Define sample quantities and any separate operating or protective validation explicitly; a static fit check is not a complete-machine safety test.
No. The linked figures describe that project's delivered package and recorded checks. Your released geometry, operating conditions and inspection plan establish acceptance for a new order.
Send the drive configuration, guard and bracket drawings, approved envelope, material, finish, BOM, quantities and inspection requirements for an engineering quotation.
For supplier qualification, specify the required standard and project scope. Confirm the applicable certificate holder, manufacturing site and document coverage before order placement.