Medical Equipment · OEM Drawings · Repeat Production

Custom Medical
Instrument Trays
Tray Bodies, Lids & Dividers

Build-to-print stainless tray components for medical equipment OEMs: perforated bodies, matching lids, removable partitions and specified locating interfaces. Share your drawings, kit arrangement and inspection plan for a project-specific fabrication quote. Prepare your medical tray RFQ · Medical equipment component capabilities

✓ Build-to-print scope
✓ Inspection by RFQ
✓ OEM approval boundary
Custom perforated stainless instrument tray with a separate lid and removable divider components
RFQ Project-defined
RFQ
Example order size
Drawing
Critical dimensions
Plan
Inspection scope
OEM
Final approval
01 / What We Fabricate

A Custom Tray Assembly, Not a Stock Hospital Supply

DRAmetal manufactures tray metalwork to released OEM drawings. Define the tray body, lid, dividers and included hardware as separate components, then coordinate their final fit and inspection. The scope can cover first articles and repeat production against an approved design.

Medical Equipment OEMs

Component fabrication for instrument-handling and equipment programs with a defined application, controlled drawings and named acceptance requirements.

Perforated Stainless Bodies

Formed and welded tray bodies with drawing-defined hole patterns, corner details and supports. Review finished dimensions rather than the flat profile alone.

Configurable Internal Parts

Removable partitions and specified locating interfaces coordinated with the permitted kit layouts, release actions and required access.

Repeat Supply

A controlled assembly package with agreed materials, finish instructions, component revisions, inspection records and packaging requirements.

Define Fabrication, Durability and Processing Validation Separately

Provide the intended application and processing requirements with the RFQ. The quote will identify the fabricated components, inspection records and expressly included validation activities; a tray material or finish alone does not establish the performance of a complete instrument-processing system.

02 / Custom Component Scope

Tray Bodies, Lids, Dividers and Locating Interfaces

Select the parts required by your OEM program. Dimensions, tolerances, materials and acceptance conditions are quoted from your drawing package rather than assigned as universal ratings.

Stainless Instrument Tray Bodies Perforated construction

Stainless Instrument Tray Bodies

Cut, formed and welded bodies with specified perforations, corner geometry and support feet. Identify the finished edge condition and the state in which flatness is accepted.

  • Pattern Released drawing
  • Corners Defined joint detail
  • Edges Specified acceptance
Matching Perforated Lids Closure interface

Matching Perforated Lids

Lids and covers coordinated with the body rim, divider envelope and selected closure hardware. Include seating datums and replacement-part interchangeability where required.

  • Seating Mating datums
  • Clearance Finished assembly
  • Hardware Selected reference
Removable Tray Dividers Configurable layout

Removable Tray Dividers

Partitions with specified clip or slot interfaces for permitted internal arrangements. Define engagement, retention, removal access and the accepted component positions.

  • Positions Approved layouts
  • Retention Agreed method
  • Removal Defined access
Feet, Clips and Locator Interfaces Assembly details

Feet, Clips and Locator Interfaces

Drawing-defined metal supports and mounting details for selected locating pads or other included components. State which purchased items are supplied by the customer or included in the quotation.

  • Supports Specified orientation
  • Locators Controlled reference
  • Scope Named BOM items
03 / Technical Capabilities

Release the Requirements That Matter to Your Assembly

Supply scope Custom tray bodies, lids, dividers, feet and expressly included hardware or assembly operations for OEM equipment programs.
Material and thickness Specified per component. The related customer project used 1.0 mm 304 stainless tray bodies and 0.8 mm 304 dividers; another design requires its own material review.
Perforations Hole geometry, location, pattern, edge distance and finished-edge criteria defined on the released drawing.
Corner and joint details Finished radii, continuous seams where specified, permitted overlaps and accessible inspection surfaces.
Divider interfaces Permitted positions, clip or slot geometry, selected locating pads, engagement and release sequence.
Lid interfaces Rim datums, finished clearance, selected latch references and approved internal envelope.
Surface treatment Project-defined electropolishing, passivation or other specified finishing route, with appearance and inspection requirements agreed before production.
Inspection First-article dimensional reports and project-specific batch coverage; visual, tactile and measured edge criteria kept distinct.
Validation inputs Test configuration, sample count, exposure conditions, acceptance limits and responsible party defined separately from routine fabrication inspection.
RFQ package CAD, drawings, controlled BOM, permitted configurations, quantities, finish requirements and requested quality records.
04 / Manufacturing Process

From Released Drawings to a Controlled Tray Assembly

01

Define the Kit

Separate tray, lid, partitions, supports and purchased locators. Identify the permitted assembly configurations and the quantity for each item.

02

Review the Interfaces

Check body and lid datums, divider positions, corner construction, perforations and supported orientation before releasing the fabrication route.

03

Fabricate the Components

Plan cutting, forming and joining against the approved component drawings, including the specified edge preparation and joint details.

04

Finish and Assemble

Apply the agreed stainless finishing route and assemble the named hardware or locators. Verify the final condition at critical mating areas.

05

Inspect the Agreed Scope

Record the dimensional and assembly checks, distinguishing first-article inspection, lot sampling and any test on every component.

06

Control Repeat Production

Close approved deviations and retain the accepted revisions, component references, finishing requirements and inspection plan.

05 / Why It Matters

Details That Make a Tray Package Easier to Accept

Review the fabricated parts as a working assembly. External dimensions alone do not describe edge contact, removable interfaces or the condition used for inspection.

Finished Perforation Edges

Define numeric burr limits and visual or tactile checks separately. A snag-free observation is useful but does not by itself measure burr height.

Divider and Lid Fit

Coordinate permitted divider positions and clip heights with the lid seating state. Identify whether replacement parts must be interchangeable.

Corners and Drainage

Review finished seams, transitions, supports and openings in the intended orientation, including the relevant assembled and disassembled states.

Documented Test Coverage

Keep component durability tests separate from routine lot inspection and validation of the complete device's processing performance.

Customer Project

Medical Instrument Tray: Removable Dividers and Steam-Cycle Durability

Materials, fabrication decisions and results for an anonymous customer project.

Medical Instrument Tray: Removable Dividers and Steam-Cycle Durability — component reference

Component reference image

The Customer Challenge

Perforation burrs scratched instruments, fixed dividers limited kit configurations, corners were difficult to access and watermarks remained after steam processing.

Project Measurements & Details

0.02–0.04 mmRecorded hole deviation
0.15–0.25 mm/mRecorded flatness
3 trays · 500 cyclesSteam-cycle validation samples

Results apply to the project configuration described on the linked page.

Read the Customer Project →
07 / Why Choose Us

Procure Defined Medical Metalwork for Your OEM Program

01

Clear Scope at Quotation

Compare offers against the same body, lid, divider and hardware package, with unresolved interfaces identified before manufacture.

02

Assembly-Focused Review

Coordinate the finished relationships between components instead of accepting an isolated set of nominal dimensions.

03

Traceable Acceptance

Agree the report, setup and sample coverage that purchasing and engineering need to release the first article and repeat lots.

04

Revision-Controlled Supply

Retain approved component identities, substitutions and finishing instructions as kit configurations develop.

09 / FAQ

Custom Medical Instrument Tray Fabrication Questions

Are these stock instrument trays for individual purchase?

This page covers custom fabrication for OEM and enterprise programs with released drawings and a defined component scope. Send the tray, lid and divider requirements with quantities so the team can review a build-to-print quotation.

Can the quote include removable dividers and matching lids?

Yes. Include each component in the BOM with the permitted configurations, selected hardware and final assembly requirements. Define retention, removal access, lid seating and any interchangeability requirement.

Which stainless steel and thickness should we use?

Specify the material and thickness for each part through your design review. The linked customer project used 304 stainless steel in a 1.0 mm body and 0.8 mm dividers; those choices are not a universal specification for all trays.

Can electropolishing and passivation be included?

These can be included in the agreed manufacturing scope. Provide the required finishing route, acceptance condition and records so the finished edges, appearance and mating interfaces can be reviewed together.

Does the customer project's steam-cycle result apply to every tray?

No. The reported 121°C, 500-cycle result belongs to three validation samples of that project's configuration. Agree durability testing for a new design separately, and define the validation responsibilities for the complete processing system.

What inspection information should accompany the RFQ?

Send the critical dimensions and datums, measurement state, edge criteria, assembly checks and requested coverage. Identify first-article reports, batch sampling and any separate exposure test, including the sample count and acceptance procedure.

Get Started

Ready to Source Your
Custom Medical Tray Assembly?

Share the tray, lid and divider drawings with kit configurations, quantities, finish requirements and the quality records your OEM program needs.

Certification documents are available for supplier qualification. Mention the required standard and project scope in your inquiry.