Formed saddles and cradle plates
Cut and formed metal contact surfaces carry the pipe onto the specified mounting feet or pedestal. Review actual pipe diameter, contour, seat width, finished height and any lining together.
DRAmetal manufactures formed saddles, split clamps and support kits for industrial equipment. Choose build-to-print production or project-reviewed structural design and load calculations. We coordinate pipe and liner fit, mounting interfaces, fixed or sliding duty, materials and inspection around the approved support design. Compare support arrangements · Order and first-article approvals
The delivered scope can include the saddle or clamp metalwork, mounting bracket, selected liner and agreed mechanical hardware. We establish which items are supplied and how they connect to the equipment. Pipework, pressure containment, plant installation and whole-system qualification are separate scopes unless explicitly agreed.
Cut and formed metal contact surfaces carry the pipe onto the specified mounting feet or pedestal. Review actual pipe diameter, contour, seat width, finished height and any lining together.
Two-part bands and drawing-defined retainers provide the approved closure arrangement. Define ear gaps, spacers, hardware, installation access and the intended contact condition.
Formed feet, welded pedestals, gussets and base plates connect the pipe interface to the equipment. Their hole patterns, seating faces and joint requirements follow the released load path.
Selected inserts and bought-in fasteners can be included against an agreed BOM. Part identity, retention, compatibility, replacement access and mixed-size packout are controlled with the metalwork.
A pipe layout and equipment mounting reference show where the support carries load, permits movement and needs service access. Add the operating conditions and design responsibility so the quotation covers the intended component or engineering package.
Choose a fabrication route around the support's duty. The approved design connects pipe envelope, material, restraint, movement and load verification for each position.
Open Contact Open curved seats with mounting feet or a defined pedestal provide access around the supported pipe. Include any uplift retainer or liner in the assembly definition.
Assembled Retention Two-piece curved bands close around a specified pipe envelope. The released design controls hardware, ear closure and the function of the pipe-to-clamp contact.
Controlled Insert A specified liner separates contact surfaces or provides an agreed compliant interface. Its compound, thickness, retention and service exposure are reviewed as part of the assembly.
Equipment Integration Common rails or brackets combine individually identified supports around a coordinated pipe layout. Keep pipe positions, movement duties, hardware access and kit contents distinguishable.
| Supply and design scope | Identify build-to-print manufacture or the required structural-design support. Provide part and assembly drawings, quantities, equipment interfaces and the release or approval responsibility. |
|---|---|
| Pipe contact envelope | State actual pipe outside diameter and tolerance, material, coating, sleeves and any insulation at the support. Distinguish nominal pipe size from the physical contact diameter. |
| Support function | Identify fixed, guided, sliding or resting duties and permitted motion in the equipment coordinate system. Mark the moving interface, installation position and required travel. |
| Loads and constraints | Provide reactions in each relevant direction, pipe and contents mass where applicable, operating and maintenance cases, temperature range, movement and mounting restraint. Agree load combinations and acceptance criteria for design calculations. |
| Metal construction | Specify material grade, thickness or section, formed profile, weld requirements, hole locations and finished mounting references. Changes to reach, pedestal height or joint geometry receive interface review. |
| Liner and fasteners | Specify liner compound, thickness, compatibility, retention and replacement requirements. Define hardware identity, washer seats, thread engagement and the approved assembly condition. |
| Surface and exposure | Describe condensation, cleaning agents, process exposure and outdoor conditions. Define finish, masking, contact surfaces, edge treatment and any permitted repair method. |
| Inspection and testing | Agree sample coverage, profile and dimensional checks, reference pipe or gauge, mounted condition, lined fit and reports. Load testing, where requested, requires a separate defined fixture, procedure and acceptance basis. |
| Identification and repeat supply | Link support position, pipe size, liner, hardware and drawing revision in the BOM. Distinguish matched sets, interchangeable parts, spares and temporary transport restraints. |
Confirm supplied items, pipe envelope, mounting structure, permitted motion and project inputs. Identify whether production follows existing drawings or includes an agreed design and calculation package.
Review the curved seat, liner stack, closure joints and complete force path. Structural work uses the supplied load cases and boundary conditions, with assumptions documented for approval.
Coordinate cutting, forming, welding and any secondary machining around the released profile and mounting references. Check features before later assembly restricts access.
Apply the agreed surface treatment and fit selected liners and mechanical hardware. Keep coated, masked and moving contact areas consistent with the assembly requirements.
Record contour, mounting dimensions and the specified closure or movement checks under the agreed setup. Keep dimensional findings separate from any project-specific structural test results.
Obtain the applicable customer first-article approval, preserve revision identity and protect finished contacts. Pack mixed diameters and hardware by their agreed assembly positions.
A support can fit around the pipe and still behave differently from the design intent. Resolve these connected interfaces before releasing metalwork.
Actual outside diameter, coating and liner thickness determine the contact stack. Keep free liner dimensions and installed closure separate so substitutions can be assessed.
Define which motion is restrained and how the force is transferred. A sliding interface, frictional restraint and positive stop each need their own design conditions.
Pipe-center height, bracket reach, washer seats, welds and the receiving frame influence the complete load path. Bolt size alone does not establish support capacity.
Allow room to remove clamp halves, replace inserts and reach fasteners without disturbing adjacent lines. Review the maintenance envelope as well as the installed outline.
Start from released customer geometry or agree a structural design and load-calculation scope. Document inputs and approvals so the manufactured configuration has a clear basis.
Coordinate formed contacts, welded feet, finishing, liners and selected fasteners as one support package instead of separate uncoordinated purchases.
Agree the gauge, restraint, assembly sequence and sample quantity used for first-article checks. Reports identify what was inspected and under which conditions.
Keep position, diameter, liner and hardware revisions linked. Replacement orders preserve the accepted interface rather than relying on an approximate visual match.
Both are available within an agreed project scope. We can manufacture released customer drawings or support structural design and load calculations using supplied reactions, operating conditions, movement and mounting constraints. The calculation basis, deliverables, review and approval responsibilities are agreed before design release.
Provide actual outside diameter and tolerance, pipe material, coatings or sleeves, liner geometry and the required mounting references. Include the installed contact or clearance condition and any insulation that affects the support envelope.
Only when the approved arrangements explicitly define those different duties. Identify the moving interface, restraint mechanism, installation setting and required travel. A clamp that fits the same pipe is not automatically suitable for both functions.
They can be supplied when identified in the agreed BOM and quotation. Specify the liner compound, thickness, retention and service compatibility, along with hardware grades, finishes, washer arrangement and assembly requirements.
The accepted load conditions belong to the project-specific design and configuration. Supply force directions, combinations, operating states and mounting constraints for review. A general rating is not assigned solely from pipe diameter, plate thickness or bolt size.
Agree the sample quantity, profile and dimensional features, mounting restraint, reference pipe or gauge, liner identity and closure or movement checks. Any structural load test has a separately defined fixture, procedure and acceptance criteria.
New customers, new products, changed orders and individual orders of 100 pieces or more require customer first-article approval. An order below 20 pieces or an unchanged repeat order does not create an automatic exemption. Skipping approval requires an existing valid written waiver arrangement or a written waiver from the customer's authorized representative for the applicable part, revision and order, confirmed by our internal quality lead.
Send your pipe layout, support drawings or design brief, loads, movement, material and liner requirements, quantities and inspection scope for an engineering quotation.
Certification documents are available for supplier qualification. Mention the required standard and project scope in your inquiry.