Housing assemblies
Folded or joined walls, roofs and reinforcements coordinated with the transformer envelope and the actual installation arrangement. Specify assembled delivery or identified panel kits.
Source the fabricated enclosure around your transformer’s actual footprint, ventilation design and maintenance layout. DRAmetal supplies drawing-controlled metal housings, base rails, removable panels and agreed hardware as an OEM mechanical package, with equipment interfaces and acceptance conditions defined before production. Power distribution cabinet metalwork · Customer transformer enclosure project
The purchased scope is the empty fabricated mechanical enclosure and agreed components. We review manufacturing geometry, joining, finish and assembly fit against released OEM inputs. Transformer selection, electrical design, thermal validation and complete-equipment approvals remain distinct responsibilities; a metal housing alone does not establish those results.
Folded or joined walls, roofs and reinforcements coordinated with the transformer envelope and the actual installation arrangement. Specify assembled delivery or identified panel kits.
Fabricated support members with approved contact pads, mounting slots and enclosure attachment points. Release equipment loads and support conditions before selecting the construction.
Louvers, perforations and cable-entry plates manufactured to the approved pattern and orientation, with adjoining stiffeners and routes considered in the assembly review.
Service panels with selected hinges, latches and fasteners, reviewed against the approved task, handling method and available opening or withdrawal space.
Include the transformer footprint, terminal layout, support assumptions, ventilation inputs, service task and inspection requirements. These details let the quotation address the real mechanical package and identify unresolved items before manufacture.
These component images illustrate available fabrication arrangements. Final materials, dimensions, opening geometry and equipment validation follow the approved project package rather than a universal cabinet specification.
Housing Assembly Folded sheet-metal wall and roof assemblies with released ventilation patterns, mounting returns and internal exclusions. Coordinate the opening arrangement with the OEM thermal design.
Equipment Support Formed or welded bases connecting equipment feet, cabinet walls and the installation surface. Define the datum scheme, usable slot travel and approved restraint condition.
Maintenance Access Finished panels with selected attachment hardware and reinforcements. Review the complete movement path and access to the equipment, not only the closed-panel outline.
Configured Interfaces Variant-specific plates with approved entry hardware interfaces, blanking arrangements and mounting edges. Keep each pattern tied to the actual transformer and cable layout.
| Equipment configuration | Transformer drawing, footprint, terminal arrangement, installed orientation and the equipment versions that the enclosure must accommodate. A nominal power rating alone does not define these interfaces. |
|---|---|
| Supply boundary | Housing panels, base, feet, reinforcements, doors, entry plates and purchased hardware included per assembly; identify customer-supplied components and any loose spares. |
| Support and load inputs | Approved equipment mass and support locations, relevant handling or operating load cases, installation surface assumptions and any specified isolators or shims. |
| Ventilation requirements | OEM-approved inlet and outlet zones, opening geometry, obstruction limits and thermal validation responsibility. Identify additional mesh or other approved components. |
| Materials and treatment | Released material grades and thicknesses for each component, joining requirements, finish system, film-thickness plan, color, interior coverage and masked contact faces. |
| Service and cable access | Door swing or lift-off path, tool approach, equipment service task, entry hardware identity and approved cable routing or termination envelope. |
| Dimensional acceptance | Functional datums, finished-state mounting fit, door gaps, base support condition and the measurements that require an actual equipment trial or agreed fixture. |
| Inspection and release | First-article configuration, sample quantities, required reports, project-specific tests and approval authority; document any open corrections before repeat orders. |
Review the transformer footprint, enclosure envelope, ventilation zones and maintenance task together. Identify missing inputs and assign decisions before releasing fabrication details.
Confirm panel, base and hardware drawings, material and finish requirements. Separate common components from equipment-specific variants in the controlled BOM.
Produce approved panels, rails and reinforcements. Coordinate the joining sequence with the functional mounting and door-frame surfaces so later fit checks have a meaningful basis.
Apply the specified coating and masks, then install the selected mechanical hardware. Preserve variant identity through finishing and assembly rather than relying on similar outlines.
Inspect dimensions and finished fit using the agreed support condition and mating reference. Record sample scope, corrections and the distinction between mechanical checks and equipment validation.
Reconcile the accepted configuration, packing list and open actions. Protect finished edges and carry approved drawing changes into subsequent equipment batches.
Precision should control the relationships that determine installation, service and repeatability. Tight tolerances on unrelated edges do not resolve a missing equipment datum or an unreviewed cable route.
Check slots with the actual selected fastener and seating arrangement. Total slot length is not the same as available equipment adjustment.
Keep approved opening zones coordinated with reinforcements, mounting rails and cable routes. Geometry inspection and thermal validation remain separate records.
Review hinge swing, lift-off direction and tool paths with adjacent equipment present. A door that opens on an empty bench may not support the intended service task.
Separate completed part repairs from drawing changes and future improvements. A successful trial should not conceal an unresolved production instruction.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
A 12-set dry-transformer enclosure project with sampled mounting checks, a single front service door, recorded panel fit and documented slot corrections.
Results apply to the project configuration described on the linked page.
Read the Customer Project →Define the complete fabricated package, selected hardware and inspection deliverables so quotations can be compared on the same basis.
Focus dimension control on support planes, mounting patterns, panel seats and the approved equipment relationships rather than applying one tolerance to every feature.
Tie first-article records to the actual BOM, drawing revision and fixture or equipment used, preserving the scope of each result.
Keep common interfaces, variant-specific panels and approved changes traceable through manufacture, packing and future replacement supply.
This product covers custom fabricated metal enclosure packages and agreed mechanical components. The transformer, electrical wiring, protection devices and complete-equipment certification are separate scopes unless explicitly defined in the project agreement.
Yes. Provide the equipment footprint, support locations, load inputs and installation arrangement together with the enclosure drawings. The base, mounting feet and panels can then be quoted as a coordinated mechanical assembly with agreed acceptance checks.
Review each approved footprint, terminal layout, ventilation requirement and cable direction in a variant matrix. A shared outer envelope does not establish compatibility with every internal configuration. Identify common and variant-specific components in the BOM.
No individual metal feature establishes the complete-equipment result. Supply the required specification, configuration and validation plan. Fabrication checks confirm the released geometry and assembly scope; any rating or temperature claim needs applicable project evidence.
Identify the interfaces accepted in the delivered state, such as mounting fit, panel seats, entry hardware and door gaps. The agreed inspection plan should distinguish pre-finish dimensions from finished-state measurements and functional trials.
The quotation can define assembled or kit delivery. Include the assembly BOM, hardware state, part identification and packing sequence so receiving can verify each complete set and distinguish similar variants.
No. The linked results belong to the stated project and its sample scope. A new enclosure is governed by its approved equipment interfaces, drawings, materials, finish and inspection plan.
Send the equipment drawings, mechanical BOM, support inputs, ventilation geometry, materials, finish, quantities and first-article requirements for an engineering quotation.
Certification documents are available for supplier qualification. Mention the required standard and project scope in your inquiry.