Wall-Mount Wall-Mount Enclosures
Compact single-door enclosures for control panels and junction applications, with back panel and mounting provisions.
- Mount Wall / surface
- Door Single, hinged, lockable
- Rating NEMA 1/12/4/4X
Custom electrical enclosures for industrial control panels, power distribution, and automation. We fabricate customer-released designs targeting NEMA and UL-related requirements in carbon steel, 304/316 stainless, and aluminum. Final rating and listing remain with the OEM or test body.
From compact wall-mount boxes to full free-standing cabinets — we fabricate the complete range of electrical enclosures to your dimensions, rating, and component layout.
Wall-Mount Compact single-door enclosures for control panels and junction applications, with back panel and mounting provisions.
Free-Standing Large floor-mounted enclosures for full control systems, with welded leg kits, single or double doors, and full-size back panels.
Junction Box Compact boxes for wiring connections, terminals, and distribution — with knockouts, glands, and grounding to your layout.
Outdoor / Custom Enclosure metalwork with rain hoods, sun shields and seal-ready details for OEM programs targeting NEMA 3R/4/4X requirements.
These are common customer targets, not DRAmetal product ratings. The OEM, panel builder or test body owns final validation, marking and listing.
| Customer Rating Targets | NEMA 1, 3R, 4, 4X or 12 as defined by the OEM drawing and validation plan |
|---|---|
| Standards | UL 50 / UL 50E / UL 508A-related mechanical details only when specified by the OEM |
| Materials | Carbon steel, 304 / 316 stainless steel, aluminum |
| Gauge | Custom — typically 14–11 ga to application |
| Finish | ANSI 61 gray powder coat (standard); #4 brushed for stainless 4X |
| Sealing | Closed-cell gasket and compression details to the released drawing |
| Grounding | Grounding studs on body and door as defined by the OEM or panel builder |
| Doors & Latching | Single / double, hinged, lockable; multi-point latching |
| Back Panels | Powder-coated white steel sub-panels, sized to opening |
| Customization | Non-standard sizes, cutouts, knockouts, glands, HVAC openings |
Our process delivers enclosure metalwork to the released drawing. Final environmental rating and system suitability require OEM or laboratory validation.
Precision cutting of body, door, and back-panel blanks, plus cutouts, knockouts, and mounting holes to your layout.
CNC press-brake bending of the enclosure body and door to precise dimensions and clean, consistent corners.
Welded seams, leg kits and reinforcements made to drawing-defined sealing and structural details for the customer's target environment.
Grounding studs, PEM fasteners, hinges, latches, and collar studs installed for door, panel, and mounting.
Surface prep and ANSI 61 gray powder coat (or your color); brushed #4 finish for stainless 4X enclosures.
Gasket application, door and hardware assembly, back panel fit, and final QC against rating and dimensions.
Material choice drives both cost and corrosion resistance. Here's how the three families compare for electrical enclosures.
The cost-effective standard for indoor Type 1/12 applications. Powder coating provides an attractive finish and basic protection.
Excellent corrosion resistance for harsh, washdown, or outdoor environments. 316 for chloride/coastal exposure; 304 for general corrosion.
Lightweight with natural corrosion resistance. Suitable where weight reduction matters or specific grounding requirements exist.
Need help choosing? See our 304 vs 316 stainless guide and galvanized vs stainless outdoor guide.
An electrical enclosure isn't just a box. It protects equipment from the environment, protects operators from electrical hazards, and is often what an inspector signs off on before a system can be energized.
For control panels, the enclosure's NEMA/UL rating is what the inspection authority checks. The right rating, gasket, and grounding are what let a system pass inspection and energize.
Indoor, washdown, coastal, or outdoor — each demands a different material and rating. Material, pretreatment and finish must be matched to the environment. Service life remains a buyer-defined target validated by the OEM or responsible test party.
Correct cutouts, back-panel layout, and mounting provisions mean the panel builder drops components straight in — no field rework, no delays.
Grounding studs on body and door aren't optional on rated enclosures — they're a core operator-safety requirement we build in to spec.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
Disordered wiring, poor cooling, inadequate protection and unclear identification complicated maintenance.
Results apply to the project configuration described on the linked page.
Read the Customer Project →NEMA 1/3R/4/4X/12 and UL 50/508A-compatible construction — gasket, grounding, and seam details done to the rating, not guessed.
Carbon steel, 304/316 stainless, and aluminum — we match the material to your environment and budget.
Cutouts, knockouts, back-panel layout, and mounting provisions to your component drawing — drop-in ready.
From mining to outdoor industrial — enclosures that survive dust, vibration, washdown, and corrosion.
ANSI 61 powder coat and #4 stainless finishes that hold up for decades of service.
From prototypes to high-volume runs, with consistent quality and full documentation.
We can fabricate gasket, grounding, seam and finish details from an OEM drawing targeting NEMA 1, 3R, 4, 4X or 12. DRAmetal does not assign the final rating; the OEM or test body validates it.
We fabricate customer-released mechanical details used in UL-related panel programs. UL certification documentation is available on request for applicable products and components; confirm the model and listing scope for your project. The panel builder, OEM and NRTL retain responsibility for final panel testing and listing.
Carbon steel for indoor Type 1/12; 304 stainless for general corrosion/washdown; 316 stainless for coastal/chloride or aggressive environments; aluminum where weight matters. We'll recommend based on your environment and budget.
Yes — we laser-cut cutouts, knockouts, gland holes, HVAC openings, and any custom features to your component and cable layout, so the panel drops in without field modification.
Yes — powder-coated steel back/sub-panels sized to the opening, plus grounding studs, hinges, latches, and leg kits as needed. Tell us your layout and we build it complete.
We handle everything from prototype quantities to high-volume production runs. Send us your requirements and we'll confirm MOQ and pricing for your specific enclosure.
Send us your dimensions, rating, material, and component layout. Our engineering team will review the submitted information and, where the scope is complete, provide a DFM review, material recommendation, and quote.