Custom electrical enclosures for industrial control panels, power distribution, and automation. We fabricate customer-released designs targeting NEMA and UL-related requirements in carbon steel, 304/316 stainless, and aluminum. Final rating and listing remain with the OEM or test body.

✓ NEMA targets by OEM
✓ UL-related drawing review
✓ Steel / SS / aluminum
Electrical enclosure manufactured by DRAmetal
4X NEMA target
16
NEMA Targets
508A
UL-Related Scope
3
Material Families
RFQ
Custom Built
01 / Enclosure Types

Enclosures for Every Mounting & Environment

From compact wall-mount boxes to full free-standing cabinets — we fabricate the complete range of electrical enclosures to your dimensions, rating, and component layout.

Wall-mount electrical enclosure Wall-Mount

Wall-Mount Enclosures

Compact single-door enclosures for control panels and junction applications, with back panel and mounting provisions.

  • Mount Wall / surface
  • Door Single, hinged, lockable
  • Rating NEMA 1/12/4/4X
Free-standing electrical enclosure Free-Standing

Free-Standing Cabinets

Large floor-mounted enclosures for full control systems, with welded leg kits, single or double doors, and full-size back panels.

  • Mount Floor, leg kit
  • Door Single / double
  • Rating NEMA 12/4/4X
Junction box enclosure Junction Box

Junction & Terminal Boxes

Compact boxes for wiring connections, terminals, and distribution — with knockouts, glands, and grounding to your layout.

  • Mount Wall / pole
  • Entry Knockouts / glands
  • Rating NEMA 1/3R/4/4X
Outdoor NEMA 3R electrical enclosure Outdoor / Custom

Outdoor & Custom

Enclosure metalwork with rain hoods, sun shields and seal-ready details for OEM programs targeting NEMA 3R/4/4X requirements.

  • Mount Wall / pole / floor
  • Weather Rain hood, shield
  • Rating NEMA 3R/4/4X
02 / Technical Capabilities

Mechanical Features for NEMA & UL Programs

These are common customer targets, not DRAmetal product ratings. The OEM, panel builder or test body owns final validation, marking and listing.

Customer Rating Targets NEMA 1, 3R, 4, 4X or 12 as defined by the OEM drawing and validation plan
Standards UL 50 / UL 50E / UL 508A-related mechanical details only when specified by the OEM
Materials Carbon steel, 304 / 316 stainless steel, aluminum
Gauge Custom — typically 14–11 ga to application
Finish ANSI 61 gray powder coat (standard); #4 brushed for stainless 4X
Sealing Closed-cell gasket and compression details to the released drawing
Grounding Grounding studs on body and door as defined by the OEM or panel builder
Doors & Latching Single / double, hinged, lockable; multi-point latching
Back Panels Powder-coated white steel sub-panels, sized to opening
Customization Non-standard sizes, cutouts, knockouts, glands, HVAC openings
03 / Manufacturing Process

From Sheet to Finished Enclosure

Our process delivers enclosure metalwork to the released drawing. Final environmental rating and system suitability require OEM or laboratory validation.

01

Laser Cutting

Precision cutting of body, door, and back-panel blanks, plus cutouts, knockouts, and mounting holes to your layout.

02

Bending & Forming

CNC press-brake bending of the enclosure body and door to precise dimensions and clean, consistent corners.

03

Welding & Seams

Welded seams, leg kits and reinforcements made to drawing-defined sealing and structural details for the customer's target environment.

04

Hardware Insertion

Grounding studs, PEM fasteners, hinges, latches, and collar studs installed for door, panel, and mounting.

05

Powder Coating

Surface prep and ANSI 61 gray powder coat (or your color); brushed #4 finish for stainless 4X enclosures.

06

Gasket & Assembly

Gasket application, door and hardware assembly, back panel fit, and final QC against rating and dimensions.

04 / Material Options

The Right Material for the Environment

Material choice drives both cost and corrosion resistance. Here's how the three families compare for electrical enclosures.

Carbon Steel

The cost-effective standard for indoor Type 1/12 applications. Powder coating provides an attractive finish and basic protection.

  • Corrosion Basic (coated)
  • Cost Lowest
  • Best for Indoor, controlled environments

304 / 316 Stainless

Excellent corrosion resistance for harsh, washdown, or outdoor environments. 316 for chloride/coastal exposure; 304 for general corrosion.

  • Corrosion Excellent
  • Finish #4 brushed (4X)
  • Best for Washdown, outdoor, NEMA 4X

Aluminum

Lightweight with natural corrosion resistance. Suitable where weight reduction matters or specific grounding requirements exist.

  • Corrosion Good (natural)
  • Weight Lightest
  • Best for Weight-sensitive, outdoor

Need help choosing? See our 304 vs 316 stainless guide and galvanized vs stainless outdoor guide.

05 / Why It Matters

The Enclosure Protects Equipment — and People

An electrical enclosure isn't just a box. It protects equipment from the environment, protects operators from electrical hazards, and is often what an inspector signs off on before a system can be energized.

Rating Gates Approval

For control panels, the enclosure's NEMA/UL rating is what the inspection authority checks. The right rating, gasket, and grounding are what let a system pass inspection and energize.

Environment Drives Material

Indoor, washdown, coastal, or outdoor — each demands a different material and rating. Material, pretreatment and finish must be matched to the environment. Service life remains a buyer-defined target validated by the OEM or responsible test party.

Fit Saves Field Time

Correct cutouts, back-panel layout, and mounting provisions mean the panel builder drops components straight in — no field rework, no delays.

Grounding Is Safety

Grounding studs on body and door aren't optional on rated enclosures — they're a core operator-safety requirement we build in to spec.

Customer Project

Industrial Control Box: Wiring Layout and Cooling

Materials, fabrication decisions and results for an anonymous customer project.

Industrial Control Box: Wiring Layout and Cooling — component reference

Component reference image

The Customer Challenge

Disordered wiring, poor cooling, inadequate protection and unclear identification complicated maintenance.

Project Measurements & Details

≤30 KTemperature rise
IP54Protection test
500 × 400 × 200 mmBox size

Results apply to the project configuration described on the linked page.

Read the Customer Project →
07 / Why Choose Us

Why OEMs Trust DRAmetal for Enclosures

01

Rating expertise

NEMA 1/3R/4/4X/12 and UL 50/508A-compatible construction — gasket, grounding, and seam details done to the rating, not guessed.

02

Material range

Carbon steel, 304/316 stainless, and aluminum — we match the material to your environment and budget.

03

Built to your layout

Cutouts, knockouts, back-panel layout, and mounting provisions to your component drawing — drop-in ready.

04

Proven in harsh sites

From mining to outdoor industrial — enclosures that survive dust, vibration, washdown, and corrosion.

05

Quality finish

ANSI 61 powder coat and #4 stainless finishes that hold up for decades of service.

06

Volume & consistency

From prototypes to high-volume runs, with consistent quality and full documentation.

09 / FAQ

Electrical Enclosure FAQ

Can you support NEMA rating targets?

We can fabricate gasket, grounding, seam and finish details from an OEM drawing targeting NEMA 1, 3R, 4, 4X or 12. DRAmetal does not assign the final rating; the OEM or test body validates it.

Are your enclosures UL 508A compatible?

We fabricate customer-released mechanical details used in UL-related panel programs. UL certification documentation is available on request for applicable products and components; confirm the model and listing scope for your project. The panel builder, OEM and NRTL retain responsibility for final panel testing and listing.

Which material should I choose?

Carbon steel for indoor Type 1/12; 304 stainless for general corrosion/washdown; 316 stainless for coastal/chloride or aggressive environments; aluminum where weight matters. We'll recommend based on your environment and budget.

Can you cut custom holes and knockouts?

Yes — we laser-cut cutouts, knockouts, gland holes, HVAC openings, and any custom features to your component and cable layout, so the panel drops in without field modification.

Do you provide back panels and mounting hardware?

Yes — powder-coated steel back/sub-panels sized to the opening, plus grounding studs, hinges, latches, and leg kits as needed. Tell us your layout and we build it complete.

What's your minimum order quantity?

We handle everything from prototype quantities to high-volume production runs. Send us your requirements and we'll confirm MOQ and pricing for your specific enclosure.

Get Started

Need Custom Electrical
Enclosures?

Send us your dimensions, rating, material, and component layout. Our engineering team will review the submitted information and, where the scope is complete, provide a DFM review, material recommendation, and quote.

✓ RFQ-based DFM review ✓ OEM-defined NEMA targets ✓ Steel / SS / aluminum ✓ Fully custom