Cabinet Panels and Covers
Outer panels, side covers, doors, top plates and access panels for BESS and energy infrastructure cabinets.
Custom formed panels, brackets, trays, covers, airflow baffles and mechanical kits for BESS, battery modules, renewable energy enclosures and power infrastructure equipment. DRAmetal manufactures build-to-print parts with controlled interfaces, finish protection and project-level packout for OEM integration.
Energy storage OEMs often need repeated sheet metal parts across cabinets, module racks, cable zones, airflow channels and service-access areas, supplied as controlled platform kits rather than as a single battery enclosure.
Outer panels, side covers, doors, top plates and access panels for BESS and energy infrastructure cabinets.
Battery module brackets, shelves, rails, trays and formed supports for repeated installation interfaces.
Baffles, ducts, vent plates, louvers and airflow shields for thermal management zones.
Revision-controlled sheet metal kits packed by cabinet, module bay, project stage or installation sequence.
The OEM owns battery cell selection, electrical architecture, BMS, fire safety, thermal validation and certification. DRAmetal manufactures the released sheet metal parts, hardware-ready kits and mechanical assemblies according to the approved drawings and inspection plan.
Use this component route for mixed trays, panels, brackets, covers and structural kits across an energy-storage assembly. For a complete outdoor cabinet or battery-pack housing, use the dedicated enclosure product page.
Cabinet Formed panels, doors, top covers, access covers and gland-area plates for energy storage cabinet programs.
Module Shelves, rails, trays and formed supports used to locate battery modules, busbar zones and serviceable assemblies.
Thermal Louvers, vent grilles, baffles, ducts and deflectors that help control airflow paths inside energy storage cabinets.
Kits Finished panels, brackets and hardware-ready parts packed by cabinet revision, installation stage or project site.
| Materials | Galvanized steel, cold-rolled steel, 304/316 stainless steel, 5052/6061 aluminum and project-defined coated materials |
|---|---|
| Processes | Laser cutting, punching, bending, spot welding, MIG/TIG welding, PEM hardware insertion, powder coating, passivation and assembly |
| Part examples | Cabinet panels, battery module rails, trays, covers, brackets, louvers, baffles, cable plates, gland plates and access panels |
| Quality controls | First article, CTQ hole inspection, flatness checks, coating review, hardware presence check and revision packout |
| Documentation | Drawing revision, BOM, finish specification, inspection record, material certificate and packaging photo when required |
| Delivery format | Loose parts, cabinet kits, module-bay kits, assembly-ready hardware-installed parts or export-protected project packs |
Confirm BESS, battery module, renewable enclosure or power infrastructure application and the mechanical supply boundary.
Review interfaces, thicknesses, coating notes, grounding areas, hardware, airflow features and revision control.
Laser cut, punch, bend, weld and deburr panels, brackets, trays and airflow parts to released drawings.
Apply coating, passivation or plating, then install PEM hardware, studs, hinges or drawing-defined hardware where needed.
Check CTQ holes, mounting faces, gasket lands, module rails, finish quality and assembly-critical features.
Pack finished sheet metal parts by cabinet, module bay, installation sequence, drawing revision or project phase.
Energy storage sheet metal parts sit between electrical, thermal, structural and service requirements. Small mechanical errors can affect module installation, cable routing, airflow, sealing and field maintenance.
Brackets, rails and trays must hold hole positions and datums so repeated battery modules install without rework.
Baffles, louvers and vent plates must match the system airflow strategy instead of becoming restrictions.
Coating, galvanic compatibility and edge protection matter for long-life energy infrastructure cabinets.
Energy projects often change by cabinet generation, site requirement or module supplier, so packout must follow revision control.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
Different finishes gave inconsistent corrosion protection, battery supports lacked capacity and mounting holes were not interchangeable.
Results apply to the project configuration described on the linked page.
Explore Customer Projects →Battery trays, BESS enclosures, module racks and power cabinets give us practical experience with energy equipment interfaces.
Cutting, bending, welding, finishing, hardware insertion and mechanical assembly can be coordinated under one supplier.
CTQ holes, module support faces, gasket lands, cable zones and hardware are checked against the drawing intent.
Parts can be packed by cabinet, module bay, site, revision or build sequence to reduce OEM sorting work.
We fabricate cabinet panels, doors, covers, brackets, battery module rails, trays, baffles, louvers, cable plates, gland plates and hardware-ready mechanical kits.
We normally supply the mechanical sheet metal parts and assemblies. Battery cells, BMS, electrical integration, fire safety and system certification remain with the OEM or integrator.
Yes. Parts can be packed by drawing revision, cabinet, module bay, installation sequence or project phase.
Send drawings, STEP files, material and finish requirements, BOM, hardware list, CTQ dimensions, packout preference, annual volume and prototype quantity.
Send your drawings, BOM, material and coating notes, module interface requirements, hardware list, airflow features and expected quantities. We will review manufacturability, inspection and packout risks before quoting.