HVAC · Climate Control

HVAC & RTU
Enclosure
Fabrication

Custom HVAC cabinets — rooftop unit (RTU) enclosures, air handler casings, and condensing unit housings — in galvanized steel, stainless, and aluminum. Double-wall insulated, weatherproof, low-leakage construction with access doors and drainage. We build the sheet metal cabinet; you integrate the coils, fans, and refrigeration.

✓ Double-wall insulated
✓ Low air leakage
✓ Integration-ready
HVAC RTU enclosure cabinet by DRAmetal
OEM leakage target
2-wall
Insulated Panels
RFQ
Finish Test Scope
OEM
Leakage Target
G-90
Galvanized Steel
01 / What We Fabricate

The HVAC Cabinet — Weatherproof Housing for the Equipment

An HVAC unit's cabinet has to keep weather out, hold insulation, seal against air leakage, and open up for service. We fabricate the sheet metal enclosure, built around the coils, fans, and components you'll integrate.

Cabinet & Wall Panels

Double-wall insulated panels — solid inner skin, outer skin, and foam insulation between — for thermal performance and acoustic damping, with double-flanged edges for rigidity.

Base Rails & Frame

Heavy-gauge galvanized base rails and frame that carry the equipment and seal to the roof curb — the structural foundation of the unit.

Access Doors & Panels

Insulated, hinged access doors and removable panels with rain-break overhangs and weathertight seals — so technicians can reach filters, coils, and controls.

Drainage & Openings

Sloped roof sections for drainage, condensate pan provisions, and sealed openings for piping, conduit, ductwork, and fan discharge.

Our scope: the sheet metal cabinet

We fabricate the HVAC enclosure — wall panels, base rails, access doors, drainage, and openings — formed, welded or riveted, insulated, and finished, ready for equipment integration. Bought-out components such as compressors, evaporator and condenser coils, fans and motors, the refrigeration system, heating elements, and controls/DDC are integrated by you or your assembly partner. We build the cabinet with openings and provisions sized to your equipment.

02 / Enclosure Types

Cabinets for Every HVAC Platform

We fabricate the enclosure for the full range of HVAC equipment, to your design and specification.

Rooftop unit RTU enclosure RTU

Rooftop Unit (RTU) Cabinets

Self-contained rooftop unit enclosures — robust, weatherproof cabinets that house the complete packaged system for outdoor roof mounting.

  • Use Packaged rooftop HVAC
  • Material G-90 galvanized steel
  • Build Double-wall insulated
Air handler AHU casing AHU

Air Handler (AHU) Casings

Modular air handling unit casings with double-wall insulated panels — low-leakage, low-deflection construction for indoor and rooftop air handlers.

  • Use Air handling units
  • Panel Double-wall, low-leak
  • Format Modular sections
Condensing unit housing Condensing

Condensing Unit Housings

Outdoor condensing unit enclosures with ventilation grilles and louvers, weatherproof construction, and corrosion protection for the field.

  • Use Outdoor condensing units
  • Material Galvanized / aluminum
  • Feature Ventilation louvers
Outdoor HVAC equipment enclosure Outdoor

Outdoor Equipment Enclosures

Custom weatherproof enclosures for outdoor HVAC and climate-control equipment — DOAS, makeup air, and specialized units to your design.

  • Use DOAS, makeup air, custom
  • Rating Weatherproof
  • Build Insulated, sealed
03 / Technical Capabilities

Weatherproof, Insulated, Low-Leakage

An HVAC cabinet has to seal against air leakage, insulate, survive the weather, and stay rigid under static pressure. Here's what we fabricate to.

Materials G-90 galvanized steel; aluminized steel; stainless (drain pans); aluminum
Panel Construction Double-wall — solid inner skin, outer skin, foam insulation between (e.g. 2 in.)
Air Leakage Buyer-defined leakage target; the OEM or selected test party owns configured-unit testing and performance validation
Panel Deflection Stiff panels — deflection targets (e.g. L/240) under design static pressure
Corrosion Drawing-defined coating system; any ASTM B117 method, duration and acceptance criteria are set by the buyer and validated by its test party
Sealing Continuous seals between panels, doors, and openings; sealed piping/conduit entries
Access Insulated hinged doors, removable panels, rain-break overhangs, weathertight seals
Drainage Sloped roof sections, upturned base-pan flanges, condensate pan provisions
Construction Machine-formed for precision; welded or pop-riveted; self-locking seam options

We fabricate the cabinet to your drawing, with openings and provisions sized to your equipment. Compressors, coils, fans, motors, refrigeration, heating elements, and controls are integrated by you or your assembly partner.

04 / Manufacturing Process

From Galvanized Sheet to HVAC Cabinet

An HVAC cabinet lives or dies on sealing, insulation, and weatherproofing. Our process delivers a cabinet that's airtight, rigid, and field-ready.

01

DFM & Layout

Review your equipment layout and specs — confirm material, panel construction, insulation, opening positions, and the sealing and drainage approach.

02

Laser Cutting

Fiber laser cutting of panels, base rails, and all openings — for coils, fans, ductwork, piping, conduit, and access doors, to precise position.

03

Forming

CNC press-brake forming — double-flanged edges for rigidity, machine-bent for precise assembly, with self-locking seams where specified.

04

Assembly & Insulation

Welding or pop-riveting the cabinet, building double-wall insulated panels, installing access doors with seals, and continuous sealing against air leakage.

05

Finishing

Galvanized, pre-coated, or powder-coat finish — with drawing-defined corrosion protection for outdoor durability in the field.

06

Inspection

Dimensional inspection of openings and mounting, panel fit, seal integrity, and finish inspection before delivery for your equipment integration.

05 / Why It Matters

What Makes an HVAC Cabinet Perform

The cabinet determines whether the unit is efficient, quiet, and durable. Four things separate a good HVAC enclosure from one that wastes energy and fails early.

Low Air Leakage

Conditioned-air leakage affects system efficiency. The HVAC OEM defines the allowable leakage, test method and acceptance criteria; DRAmetal does not claim a fixed percentage.

Insulation & Rigidity

Double-wall insulated panels reduce thermal loss and noise, and resist deflection under static pressure — a flexing panel leaks and transmits noise.

Weather & Corrosion Protection

Rooftop units face sun, rain, snow and wind. Drainage, sealing and coating requirements must follow the buyer's site exposure and service-life target; the OEM owns environmental validation.

Serviceability

Technicians need to reach filters, coils, and controls. Insulated access doors with weathertight seals and rain-break overhangs make service fast without compromising the seal.

Customer Project

Commercial HVAC Housing: Panel Fit and Outdoor Finish

Materials, fabrication decisions and results for an anonymous customer project.

Commercial HVAC Housing: Panel Fit and Outdoor Finish — component reference

Component reference image

The Customer Challenge

Corrosion, weak fan-guard stiffness and large assembly gaps affected the original housing.

Project Measurements & Details

IPX4Water protection
≤0.5 mmAssembly gap
1.2 mmGalvanized sheet

Results apply to the project configuration described on the linked page.

Read the Customer Project →
07 / Why Choose Us

Why OEMs Trust DRAmetal for HVAC Enclosures

01

Double-wall construction

Insulated double-wall panels for thermal performance, acoustic damping, and rigidity under static pressure.

02

Low-leakage sealing

Continuous sealing and tight construction that holds cabinet air leakage low — protecting unit efficiency.

03

Weather and coating inputs

Sloped drainage, sealed openings and finish details follow the released drawing. Corrosion targets and any salt-spray validation are buyer-owned.

04

Serviceable access

Insulated hinged doors with rain-break overhangs and weathertight seals for fast field service.

05

Integration-ready

Openings and provisions sized to your coils, fans, refrigeration, and controls for clean assembly.

06

Prototype to volume

From a first cabinet through OEM production runs, with consistent panel fit and DFM feedback.

09 / FAQ

HVAC & RTU Enclosure FAQ

Do you build complete HVAC units or just the cabinet?

We fabricate the sheet metal cabinet — wall panels, base rails, access doors, drainage, and openings — insulated, sealed, and finished. Compressors, coils, fans, motors, the refrigeration system, heating elements, and controls/DDC are integrated by you or your assembly partner. We design the cabinet with openings and provisions sized to your equipment.

What is double-wall construction?

A double-wall panel has a solid inner skin, an outer skin, and foam insulation between them (commonly 2 inches). It provides thermal insulation, acoustic damping, and rigidity — far better than a single-skin panel for performance and durability.

How do you control air leakage?

Through tight construction and continuous sealing between panels, access doors, and openings, plus sealed piping and conduit entries. The HVAC OEM owns the leakage target and system test; DRAmetal fabricates and inspects the released mechanical interfaces.

Are the enclosures weatherproof and corrosion-resistant?

We can fabricate drawing-defined drainage, openings, door overhangs and coating interfaces. The buyer specifies the material and finish. Any ASTM B117 method, duration, acceptance criteria and completed-unit weather validation remain with the OEM or selected test provider.

Can you match our existing unit design?

Yes — send us drawings or a sample and we'll fabricate the cabinet to match, including panel construction, access door layout, opening positions, and provisions sized to your coils, fans, and components.

What's your minimum order quantity?

We support everything from a single cabinet to OEM volume production. Send us your unit design and requirements and we'll confirm MOQ and pricing for your project.

Get Started

Need an HVAC or RTU
Cabinet Fabricated?

Send us your unit design, equipment layout, and environment. Our engineering team will review the submitted information and, where the scope is complete, provide a DFM review, a material, insulation, and sealing recommendation, and a quote for the sheet metal cabinet.

✓ RFQ-based DFM review ✓ Double-wall insulated ✓ Low air leakage ✓ Integration-ready