Outdoor Electrical Enclosures
Wall-mount, pole-mount and floor-standing cabinet bodies with rain lips, gasketed doors and cable entry control.
Build-to-print sheet metal enclosures, doors, gasketed panels, cable entry plates, rain hoods and hardware kits for OEM-defined IP54, IP65 and IP66 targets and external validation.
Outdoor equipment buyers need custom IP-target sheet metal enclosures with controlled gasket lands, door compression, penetrations and drainage matched to the released IP54, IP65 or IP66 design target.
Wall-mount, pole-mount and floor-standing cabinet bodies with rain lips, gasketed doors and cable entry control.
304/316 stainless boxes, covers and panels for washdown, wet-room and corrosion-prone equipment areas.
Doors, access covers, gland plates and removable panels with controlled sealing surfaces and hardware.
Finished enclosure parts packed by model, revision and hardware list for OEM integration or field installation.
DRAmetal manufactures the enclosure body, panels, doors, gland plates, hardware-ready features and finish to released drawings. The OEM or test lab owns final IP/NEMA validation, electrical equipment, gasket selection approval and system certification.
The product scope includes IP65 sheet metal enclosures, IP66 stainless enclosures and other custom IP-rated housings built around the released equipment interfaces.
IP54/IP65 Compact gasketed boxes and control housings for outdoor panels, junctions and equipment interfaces.
IP65/IP66 Floor-standing cabinet bodies, doors and back panels with gasket, latch, grounding and coating control.
Boxes Small and medium electrical boxes with cable glands, knockouts, grounding studs and gasketed access covers.
Outdoor Outdoor cabinet panels, rain hoods, drip lips, gland plates and removable covers packed as enclosure kits.
| Rating targets | Buyer-defined IP or NEMA targets based on released drawings; OEM or test provider owns validation |
|---|---|
| Materials | Powder-coated carbon steel, galvanized steel, 5052/6061 aluminum, 304 stainless and 316L stainless steel |
| Processes | Laser cutting, punching, bending, welding, grinding, hardware insertion, gasket-land preparation, powder coating, passivation and assembly |
| Sealing features | Gasket lands, rain lips, drip edges, gland plates, cable entries, hinge/latch positions, drain paths and protected hardware |
| Quality controls | First article, door fit, latch compression review, gasket surface checks, hole pattern inspection, coating review and hardware presence |
| Delivery format | Loose panels, hardware-installed enclosures, finished boxes, cabinet kits or project-specific packout by model and revision |
Clarify whether the enclosure faces rain, hose spray, dust, washdown, corrosion, immersion risk or a NEMA requirement.
Review gasket lands, door gaps, hinge/latch locations, cable entries, drain paths and coating thickness risks.
Cut, punch, bend, weld and deburr enclosure bodies, doors, covers, gland plates, rain hoods and brackets.
Apply coating or passivation, then install hinges, latches, PEM hardware, grounding studs and customer-defined hardware.
Check CTQ sealing surfaces, door fit, latch compression, gland plate holes, coating quality and hardware presence.
Pack enclosures and panel kits by model, drawing revision, installation sequence or OEM assembly station.
An IP rating is achieved by the complete enclosure system. Sheet metal flatness, gasket compression, door alignment, cable entry treatment and coating thickness all affect whether the final assembly can pass validation.
Forming, welding and coating can distort gasket lands, so CTQ surfaces need explicit checks.
Gland plates and knockouts must match the cable layout without breaking the enclosure's intended sealing path.
Material, coating and hardware choices need to match rain, salt, chemicals or washdown exposure.
The OEM normally owns final IP testing, while DRAmetal controls the manufactured interfaces to the released drawing.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
Disordered wiring, poor cooling, inadequate protection and unclear identification complicated maintenance.
Results apply to the project configuration described on the linked page.
Read the Customer Project →Electrical, telecom, solar, control and industrial enclosures give us practical sealing and hardware control experience.
Cutting, forming, welding, coating, hardware insertion and kit packout are coordinated around the same drawing revision.
Gasket lands, door openings, gland plates, latch positions and grounding points are checked as functional features.
We manufacture IP-ready mechanical parts while the OEM or test lab owns final enclosure validation and certification.
DRAmetal manufactures IP-ready mechanical interfaces to released drawings and provides the agreed inspection records. UL certification documentation is available on request for applicable products and components; confirm the model and listing scope separately. The IP65 or IP66 target, complete enclosure configuration and validation plan are agreed with the OEM and accredited test laboratory.
We fabricate enclosure bodies, doors, covers, gland plates, rain hoods, mounting brackets, back panels, access panels and hardware-installed kits.
Common choices include powder-coated carbon steel, galvanized steel, aluminum, 304 stainless and 316L stainless. The right material depends on corrosion, washdown and cost requirements.
Send drawings, STEP files, target IP or NEMA rating, material and finish notes, gasket details, cable entry layout, hardware list, CTQ sealing dimensions and forecast quantity.
Send your enclosure drawings, target IP/NEMA rating, gasket details, cable entry layout, material and finish notes, hardware list and quantities. We will review manufacturability and sealing-interface risk before quoting.