Liquid Cooling Cold Plate Manufacturer

Liquid Cooling
Cold Plates
Leak-Tested Thermal Hardware

Build-to-print aluminum liquid cooling plates for battery energy storage, EV modules, robotics, power electronics and industrial thermal systems. DRAmetal supports channel plate fabrication, controlled joining, port installation, flatness inspection and documented leak testing for OEM integration.

✓ Build-to-print scope
✓ Inspection by RFQ
✓ OEM approval boundary
Aluminum liquid cooling cold plates inspected at an industrial quality station
RFQ Project-defined
RFQ
Example order size
Drawing
Critical dimensions
Plan
Inspection scope
OEM
Final approval
01 / What We Fabricate

Cold Plates Built Around Real Thermal Interfaces

Cooling-plate buyers need controlled channels, port geometry, flatness and leak-test evidence for the heat-transfer plate itself, separate from the manifold or surrounding enclosure.

Battery Contact Surfaces

Plate flatness, mounting holes and protected contact faces are controlled around battery module or power-device interfaces.

Internal Flow Paths

Channel geometry, cover plates and joined seams follow the released thermal design and approved manufacturing route.

Ports and Connections

Inlet and outlet bosses, fittings and tube interfaces are located and inspected against assembly datums.

Leak-Tested Delivery

Pressure or leak testing, drying, cleanliness protection and revision records are supplied to the agreed RFQ scope.

Our scope: build-to-print cold plate manufacturing and inspection

The OEM owns channel design, thermal simulation, coolant selection, flow and pressure targets, battery or electronics safety, and final system validation. DRAmetal manufactures the released cold plate assembly to the agreed material, joining, inspection, test and cleanliness requirements.

02 / Cold Plate Applications

Cooling Plates for Batteries, Robotics and Electronics

The same core controls apply across applications: stable contact geometry, repeatable coolant paths, reliable joined seams and clean, protected delivery.

BESS Battery Cold Plates BESS

BESS Battery Cold Plates

Large-format aluminum cooling plates for stationary battery modules and energy storage thermal-management assemblies.

  • Materials 6061 / 3003 aluminum
  • Control Flatness and ports
  • Testing Pressure / leak plan
EV Module Cooling Plates EV

EV Module Cooling Plates

Module-level plates and cooling panels with controlled mounting, hose connections and cell-contact surfaces.

  • Format Module or pack zone
  • Features Ports and brackets
  • Supply Prototype to series
Robotics and Electronics Cold Plates Precision

Robotics and Electronics Cold Plates

Compact plates for robotic actuators, drives, power modules and industrial electronics with dense mechanical interfaces.

  • Use Drives and power devices
  • Control Hole and face datums
  • Finish Drawing-defined
Custom Channel Plate Assemblies Custom

Custom Channel Plate Assemblies

Drawing-defined channel plates, covers, manifolding features and port hardware supplied as inspected thermal assemblies.

  • Route Brazed / joined
  • Inspection FAI and leak test
  • Packout Clean and sealed
03 / Technical Capabilities

Typical Liquid Cooling Cold Plate Scope

Materials 6061, 6063 and 3003 aluminum or drawing-defined compatible plate and braze alloys
Construction Machined or formed channel plates, cover plates, vacuum-brazed or drawing-defined joining, bosses, tubes and threaded ports
Critical controls Contact-face flatness, overall thickness, channel and port position, mounting-hole datums, joined seams and protected surfaces
Testing Visual inspection, dimensional FAI, pressure test, air-decay or helium leak test when specified, plus drying and protective sealing
Documentation Drawing revision, material records, process route, inspection results, leak-test record and packaging identification as required
Supply boundary Build-to-print cold plate manufacturing; the OEM owns thermal design, coolant selection, system sizing and final application validation
04 / Manufacturing Process

From Released Thermal Design to Leak-Tested Plate

01

Drawing and Duty Review

Confirm plate envelope, coolant, pressure, ports, mounting datums, flatness, cleanliness and required records.

02

DFM and Route Planning

Review channel access, braze lands, alloy compatibility, distortion risk, fixture strategy and test connections.

03

Plate and Port Fabrication

Machine or form channel features, prepare covers and fabricate bosses, tubes or port hardware to the released design.

04

Controlled Joining

Join the plate assembly with the approved vacuum-braze or drawing-defined process and controlled fixturing.

05

Dimensional and Leak Inspection

Verify contact geometry, mounting and port datums, then perform the specified pressure or leak-test sequence.

06

Clean, Seal and Pack

Dry internal paths, protect contact faces, seal ports and pack each plate by lot and drawing revision.

05 / Why It Matters

Controls That Protect Cooling Performance

A cold plate can look acceptable while still failing through distortion, port misalignment, internal contamination or a leak path. Manufacturing controls must follow the thermal and mechanical interfaces together.

Contact Flatness

Distortion at the battery or power-device face increases interface resistance and can create uneven temperatures.

Joined-Seam Integrity

Channel covers and port joints need a qualified route, controlled surfaces and an agreed leak-test method.

Flow-Path Cleanliness

Braze residue, chips or trapped moisture can contaminate pumps, valves and downstream system hardware.

Port and Mounting Datums

Coolant connections and mounting holes must align with the module without forcing hoses or distorting the plate.

Customer Project

Energy Storage Cold Plate: Sealing and Temperature Uniformity

Materials, fabrication decisions and results for an anonymous customer project.

Energy Storage Cold Plate: Sealing and Temperature Uniformity — component reference

Component reference image

The Customer Challenge

Weld leakage, unbalanced channels and poor flatness created uneven battery temperatures and weak thermal contact.

Project Measurements & Details

≤1 × 10⁻⁷ Pa·m³/sHelium leak rate
≤3°CBattery temperature difference
≤0.3 mm/mFlatness

Results apply to the project configuration described on the linked page.

Read the Customer Project →
07 / Why Choose Us

Why OEMs Use DRAmetal for Liquid Cooling Plates

01

Thermal hardware experience

Cold plates, coolant manifolds, heat sinks and battery structures give the team practical interface context.

02

Route-level control

Materials, channel preparation, joining, ports and testing are tied to one released manufacturing traveler.

03

Inspection around CTQs

Flatness, holes, ports, seams and leak performance are checked against the RFQ inspection plan.

04

Clean traceable delivery

Finished plates can ship dried, port-sealed, face-protected and identified by lot and revision.

09 / FAQ

Liquid Cooling Cold Plate FAQ

What cold plate applications can DRAmetal support?

Typical RFQs include BESS battery modules, EV module plates, robotics drives, power electronics and other industrial liquid-cooled hardware built to released drawings.

Can you vacuum-braze aluminum cold plates?

Vacuum-brazed construction can be supported when it matches the drawing, alloy system and qualified manufacturing route. Final process and test requirements are confirmed during RFQ review.

How are cold plates tested for leaks?

Testing may use pressure hold, air decay, water immersion or helium methods depending on the specified pressure, allowable leak rate and customer test standard.

Do you design the thermal channels?

We normally manufacture to the customer's released thermal design. DFM feedback can address manufacturability, joining access, distortion and testability, while thermal sizing and system validation remain with the OEM.

What information is needed for a cold plate quote?

Send 2D drawings, 3D models, alloy requirements, channel and port details, coolant, working and test pressure, leak-rate limit, flatness, cleanliness, finish, records and quantities.

Get Started

Need Liquid Cooling Cold Plates
Built and Leak-Tested to Drawing?

Send the cold plate drawings, materials, channel and port details, pressure, leak-rate limit, flatness, cleanliness and quantity. We will review manufacturability, joining and inspection scope before quoting.