Cabinet Frame & Body
Floor-mounted vertical cabinet sections in steel or aluminum — the structural body that houses the distribution equipment, with a base for floor or pad mounting.
Custom power distribution cabinets (PDC) — floor-mounted switchgear enclosures, busbar chambers, and distribution cabinets in steel and aluminum. Dead-front safety, compartmentalized, IEC 61439 / NEMA-aware. We build the sheet metal cabinet; you integrate the breakers, busbars, and electricals.
A power distribution cabinet houses and isolates the switchgear, busbars, and breakers that branch incoming power to many loads. We fabricate the sheet metal cabinet — the safe, compartmentalized structure around your electricals.
Floor-mounted vertical cabinet sections in steel or aluminum — the structural body that houses the distribution equipment, with a base for floor or pad mounting.
A dedicated busbar compartment that isolates the bus from the rest of the cabinet, with provisions for busbar supports and the clearances safe distribution requires.
Dead-front panels that prevent contact with live parts, plus hinged doors and removable panels for safe access to breakers and terminals during service.
Internal compartmentalization (bus, breaker, cable zones), mounting plates for equipment, and sealed cable/conduit entries top or bottom.
We fabricate the cabinet structure — frame, body, busbar chamber, dead-front panels, doors, compartments, mounting plates, and cable entries — laser-cut, formed, welded, and finished, ready for equipment integration. Bought-out components such as transformers, circuit breakers and switchgear, busbars (copper/aluminum conductors), PDU modules, protective relays and monitoring, and all electrical wiring are integrated by you or your panel builder. We build the cabinet with compartments and provisions sized to your equipment.
We fabricate the cabinet structure for the full range of power distribution applications, to your equipment and design.
Distribution Floor-mounted cabinets that branch incoming power to multiple feeder circuits — the workhorse of commercial, industrial, and data center power distribution.
Data Center High-capacity cabinet-style power distribution for data centers — branching UPS/utility power to rows of server cabinets through compartmentalized structures.
Switchgear Enclosures for low- and medium-voltage switchgear — compartmentalized, dead-front structures housing breakers, switches, and protective equipment.
MCC Motor control center cabinet sections with power bus provisions and plug-in module compartments — for industrial motor control and distribution.
A power distribution cabinet has to protect people from live parts, isolate the busbar, dissipate heat, and meet standards. Here's what we fabricate to.
| Materials | Cold-rolled steel (ASTM A366/A611), galvanized steel, stainless, aluminum |
|---|---|
| Construction | Floor-mounted vertical cabinet sections; welded/bolted frame with mounting plates |
| Dead-Front Safety | Dead-front panels preventing contact with live parts during operation |
| Busbar Chamber | Isolated busbar compartment with support provisions and required clearances |
| Compartmentalization | Separated bus, breaker, and cable zones for safety and serviceability |
| Standards Awareness | Built to support IEC 61439 / NEMA enclosure and IP-rated requirements |
| EMI / Bonding | Metal construction meeting electrical bonding and EMI-shielding requirements |
| Access & Cable | Hinged doors, removable panels, top/bottom cable and conduit entries |
| Finishing | Powder coat (RAL), galvanized; ventilation provisions for heat dissipation |
We fabricate the cabinet structure to your equipment and standards. Transformers, breakers, switchgear, busbars, PDU modules, relays, monitoring, and wiring are integrated by you or your panel builder.
A distribution cabinet has to be safe, accurate, and ready for equipment. Our process delivers a compartmentalized cabinet built to your layout and standards.
Review your equipment, busbar, and compartment layout — confirm material, standards (IEC 61439/NEMA/IP), mounting plates, and cable entry plan.
Fiber laser cutting of frame, panels, mounting plates, and compartment dividers — with breaker cutouts, ventilation, and cable openings to precise position.
CNC press-brake forming of cabinet sections and panels — accurate bends for a rigid, true cabinet that assembles cleanly with proper clearances.
Welding the frame, fitting dead-front panels, compartment dividers, busbar-support provisions, doors, and mounting plates for the electricals.
Powder coat or galvanized finish, with ventilation provisions — corrosion protection and heat dissipation for a reliable, long-service cabinet.
Dimensional inspection of compartments and mounting, clearance and fit verification, and finish inspection before delivery for your equipment integration.
A distribution cabinet houses dangerous power and critical infrastructure. Four things separate a safe, reliable cabinet from a liability.
Dead-front construction prevents contact with live parts — the core safety principle of a distribution cabinet. The structure keeps operators safe even with the cabinet energized.
An isolated busbar chamber with correct clearances is essential for safe, compliant distribution. Precise fabrication maintains the clearances that prevent faults.
High-current distribution generates heat. Ventilation provisions and proper cabinet design keep equipment within temperature limits for reliability and life.
Distribution equipment must meet IEC 61439, NEMA, and IP requirements. A cabinet built to support these — clearances, bonding, ingress protection — is the basis of a compliant system.
Materials, fabrication decisions and results for an anonymous customer project.

Component reference image
Insufficient protection and inadequate spacing between live parts and the enclosure accompanied excessive busbar temperature rise.
Results apply to the project configuration described on the linked page.
Read the Customer Project →Distribution cabinets alongside our electrical enclosures, busbar, and cable management — the full power range.
Dead-front construction that keeps operators safe from live parts — the core of a distribution cabinet.
Isolated busbar chambers and separated breaker/cable zones for safety, clearance, and serviceability.
Built to support IEC 61439, NEMA, and IP requirements — clearances, bonding, and ingress protection.
Compartments, mounting plates, and cable entries sized to your switchgear, breakers, and busbars.
From a single cabinet through production programs, with consistent quality and DFM feedback.
We fabricate the sheet metal cabinet structure — frame, body, busbar chamber, dead-front panels, doors, compartments, mounting plates, and cable entries. Transformers, circuit breakers and switchgear, busbars, PDU modules, protective relays, monitoring, and electrical wiring are integrated by you or your panel builder. We build the cabinet with compartments and provisions sized to your equipment.
Dead-front means the front of the cabinet (with or without a door) prevents the operator from contacting live electrical parts during normal operation. It's the core safety principle of a distribution cabinet — the structure keeps people safe even when the cabinet is energized.
We fabricate the cabinet to support IEC 61439, NEMA and IP target requirements defined by the OEM — providing the clearances, compartmentalization, bonding, and ingress protection these standards require. Final assembled equipment certification is completed by you or your panel builder with the installed electricals.
Yes — we fabricate an isolated busbar chamber with support provisions and required clearances, plus compartmentalization separating bus, breaker, and cable zones for safety and serviceability. The busbars and breakers themselves are supplied and installed by you.
Yes — send us drawings or your equipment layout and we'll fabricate the cabinet to match, including compartment sizing, mounting plates, breaker cutouts, busbar-support provisions, ventilation, and cable entry positions.
We support everything from a single cabinet to production programs. Send us your equipment and design requirements and we'll confirm MOQ and pricing for your project.
Send us your equipment layout, standards, and environment. Our engineering team will review the submitted information and, where the scope is complete, provide a DFM review, a material and compartment recommendation, and a quote for the sheet metal cabinet structure.