Sheet Metal Bracket Delivery and Inspection Record
A released batch of galvanized steel L-brackets, with package identification linked to five sampled parts and their recorded dimensional results.
Delivered quantity
80 pieces
Packout
2 boxes × 40 pieces
Dimensional sample
5 parts
Inspection / release
Record scope: this webpage is an anonymized delivery and inspection summary, not an original signed inspection report. The five-part sample is not an all-unit dimensional inspection of the 80-piece batch. Customer identity and the original order reference are omitted.
Configuration and release identity
L-bracket, revision A
Galvanized low-carbon steel sheet, nominal 2 mm thickness, with deburred edges. Nominal leg lengths are 80 / 50 mm and nominal width is 40 mm.
Part reference
SIM-SM-001
Lot reference
SIM-L01
Packing list reference
SIM-PL-001
Inspection reference
SIM-IR-001
Drawing revision
Rev A
Recorded status
Released —
Anonymized references: the identifiers above preserve the relationship between the part, lot, packing list and inspection summary without publishing the original customer or order identifiers.
From package to inspection sample
Two boxes, one identified lot
Both boxes contain the same part and revision under lot SIM-L01. Sample references connect the carton contents to inspection record SIM-IR-001.
On a small screen, scroll the table horizontally. Keyboard users can focus the table region and use the arrow keys.
Packing list SIM-PL-001: box and sample correspondence
Box
Part / revision
Quantity
Inspection samples
01/02
SIM-SM-001 / Rev A
40 pieces
01, 02, 03
02/02
SIM-SM-001 / Rev A
40 pieces
04, 05
Total
80 pieces
5 sampled parts
Each box measures 300 × 240 × 180 mm. Combined net weight: 6.08 kg; combined gross weight: 7.52 kg.
Five sampled parts · seven recorded characteristics
Measured results and recorded limits
All five readings for each recorded characteristic fall within its recorded limits. The range below is the minimum and maximum of those five readings; it is not an estimated range for the unmeasured parts.
Scroll horizontally on narrow screens to read all columns.
Summary of the five-part dimensional sample
Characteristic
Unit
Recorded limits
Measured min–max
Sample result
Long leg
mm
79.80–80.20
79.94–80.12
Within recorded limits
Short leg
mm
49.80–50.20
49.92–50.09
Within recorded limits
Width
mm
39.85–40.15
39.95–40.10
Within recorded limits
Thickness
mm
1.90–2.10
1.96–2.03
Within recorded limits
Designated hole diameter
mm
6.50–6.70
6.55–6.64
Within recorded limits
Designated hole spacing
mm
24.85–25.15
24.94–25.08
Within recorded limits
Bend angle
°
89.50–90.50
89.80–90.30
Within recorded limits
View all readings for samples 01–05
Values retain two decimal places as recorded. Dimensions are in millimeters; the bend angle is in degrees. Scroll the table horizontally to compare all five samples.
Recorded measurements by sample — SIM-IR-001
Characteristic
Unit
Lower limit
Upper limit
Sample 01
Sample 02
Sample 03
Sample 04
Sample 05
Long leg
mm
79.80
80.20
79.94
80.03
80.08
79.99
80.12
Short leg
mm
49.80
50.20
49.96
50.05
50.09
49.92
50.01
Width
mm
39.85
40.15
39.95
40.02
40.07
39.99
40.10
Thickness
mm
1.90
2.10
1.98
2.01
2.03
1.96
2.00
Designated hole diameter
mm
6.50
6.70
6.55
6.60
6.64
6.58
6.62
Designated hole spacing
mm
24.85
25.15
24.96
25.03
25.08
24.94
25.01
Bend angle
°
89.50
90.50
89.80
90.10
90.20
89.90
90.30
Keep the acceptance scope attached to the data
What this record covers
Inspection coverage
Five parts were sampled from the 80-piece batch. Hole diameter and hole spacing each cover one designated feature; they do not represent every hole or every hole-to-hole relationship. The sample results do not establish all-unit conformity for all 80 parts.
Measurement methods
The recorded tool categories are caliper, micrometer, angle gauge. These results describe this part, revision and sample only; they are not a general tolerance or process-capability commitment.
Release record
The recorded inspection and release date is . This public summary retains the release status without reproducing signatures, names or the private source document.
Apply the right scope to your order